Under normal conditions, ventilation-perfusion coupling keeps ventilation (V) at approximately 4 L/min and normal perfusion (Q) at approximately 5 L/min. Thus, at rest, a normal V/Q ratio is 0.8. [2] Any deviation from this value is considered a V/Q mismatch.
On average, 4 liters of oxygen (V) and 5 liters of blood (Q) enter the alveoli in a minute, thus the normal V/Q ratio is 0.8. [10] It is considered abnormal when the ratio is greater or smaller than 0.8 and is referred to as ventilation-perfusion mismatch(V/Q mismatch).
An area with ventilation but no perfusion (and thus a V/Q undefined though approaching infinity) is termed "dead space". [6] Of note, few conditions constitute "pure" shunt or dead space as they would be incompatible with life, and thus the term V/Q mismatch is more appropriate for conditions in between these two extremes.
Hypoxemia is caused by five categories of etiologies: hypoventilation, ventilation/perfusion mismatch, right-to-left shunt, diffusion impairment, and low PO 2. Low PO 2 and hypoventilation are associated with a normal alveolar–arterial gradient (A-a gradient) whereas the other categories are associated with an increased A-a gradient. [11]: 229
A pulmonary shunt occurs as a result of blood flowing right-to-left through cardiac openings or in pulmonary arteriovenous malformations. [clarification needed] The shunt which means V/Q = 0 for that particular part of the lung field under consideration results in de-oxygenated blood going to the heart from the lungs via the pulmonary veins.
The Shunt equation (also known as the Berggren equation) quantifies the extent to which venous blood bypasses oxygenation in the capillaries of the lung. “Shunt” and “ dead space “ are terms used to describe conditions where either blood flow or ventilation do not interact with each other in the lung, as they should for efficient gas ...
An abnormally increased A–a gradient suggests a defect in diffusion, V/Q mismatch, or right-to-left shunt. [5] The A-a gradient has clinical utility in patients with hypoxemia of undetermined etiology. The A-a gradient can be broken down categorically as either elevated or normal. Causes of hypoxemia will fall into either category.
A ventilation/perfusion lung scan, also called a V/Q lung scan, or ventilation/perfusion scintigraphy, is a type of medical imaging using scintigraphy and medical isotopes to evaluate the circulation of air and blood within a patient's lungs, [1] [2] in order to determine the ventilation/perfusion ratio.