  1. Results From The WOW.Com Content Network
  2. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  3. Generator interlock kit - Wikipedia

    en.wikipedia.org/wiki/Generator_Interlock_Kit

    The external mains feeds the panel, but the panel cannot backfeed the generator. Backfeeding the generator should never be done, because it serves no purpose and risks damaging the generator. In generator mode, the backfeed breaker is on, accepting power from the generator into the panel, and the main breaker is off, isolating the external mains.

  4. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    Once the ATS sees that the generator is ready to provide electric power, the ATS breaks the home's connection to the electric utility and connects the generator to the home's main electrical panel. The generator supplies power to the home's electric load, but is not connected to the electric utility lines.

  5. Synchronization (alternating current) - Wikipedia

    en.wikipedia.org/wiki/Synchronization...

    An alternative technique used a similar scheme to the above except that the connections of two of the lamps were swapped either at the generator terminals or the system terminals. In this scheme, when the generator was in synchronism with the system, one lamp would be dark, but the two with the swapped connections would be of equal brightness.

  6. Camlock (electrical) - Wikipedia

    en.wikipedia.org/wiki/Camlock_(electrical)

    Another version is the Posi-Lok, which features keyed, shrouded connectors, and panels with sequencing interlocks. [3] Camlock is generally used where temporary connections of 3-phase and/or more than 50 A are needed. Applications include connecting large temporary generators or load banks to distribution panels or building disconnects. Common ...

  7. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    Mains electricity or utility power, grid power, domestic power, and wall power, or, in some parts of Canada, hydro, is a general-purpose alternating-current (AC) electric power supply. It is the form of electrical power that is delivered to homes and businesses through the electrical grid in many parts of the world.