When.com Web Search

  1. Ad

    related to: pressure transmitter calibration procedure diagram labeled

Search results

  1. Results From The WOW.Com Content Network
  2. Instrumentation in petrochemical industries - Wikipedia

    en.wikipedia.org/wiki/Instrumentation_in...

    A rising pressure in the vessel results in the PCV opening to feed more gas forward. If the pressure continues to rise some controllers then act to open a second PCV that feeds excess gas to the flare system. The pressure transmitter is configured to provide warning alarms (PAL and PAH) if the pressure exceeds set high and low limits.

  3. Pneumatic actuator - Wikipedia

    en.wikipedia.org/wiki/Pneumatic_actuator

    20 kPa means there is no pressure, 100 kPa means there is full range pressure (can be varied by the transmitters calibration points). As the pressure rises in the vessel, the output of the transmitter rises, this increase in pressure is sent to the valve, which causes the valve to stroke downward, and start closing the valve, decreasing flow ...

  4. Calibration - Wikipedia

    en.wikipedia.org/wiki/Calibration

    As an example, a manual process may be used for calibration of a pressure gauge. The procedure requires multiple steps, [12] to connect the gauge under test to a reference master gauge and an adjustable pressure source, to apply fluid pressure to both reference and test gauges at definite points over the span of the gauge, and to compare the ...

  5. Piping and instrumentation diagram - Wikipedia

    en.wikipedia.org/wiki/Piping_and_instrumentation...

    Piping and instrumentation diagram of pump with storage tank. Symbols according to EN ISO 10628 and EN 62424. A more complex example of a P&ID. A piping and instrumentation diagram (P&ID) is defined as follows: A diagram which shows the interconnection of process equipment and the instrumentation used to control the process.

  6. Pressure measurement - Wikipedia

    en.wikipedia.org/wiki/Pressure_measurement

    Pressure is an expression of the force required to stop a fluid from expanding, and is usually stated in terms of force per unit area. A pressure sensor usually acts as a transducer; it generates a signal as a function of the pressure imposed. Pressure sensors can vary drastically in technology, design, performance, application suitability and ...

  7. Load cell - Wikipedia

    en.wikipedia.org/wiki/Load_cell

    Annual re-calibration is considered best practice by many load cell users for ensuring the most accurate measurements. Standard calibration tests will use linearity and repeatability as a calibration guideline as these are both used to determine accuracy. Calibration is conducted incrementally starting working in ascending or descending order.

  8. Separator (oil production) - Wikipedia

    en.wikipedia.org/wiki/Separator_(oil_production)

    Pressure is maintained on the separator by use of a gas backpressure valve on each separator or with one master backpressure valve that controls the pressure on a battery of two or more separators. The optimum pressure to maintain on a separator is the pressure that will result in the highest economic yield from the sale of the liquid and ...

  9. Current loop - Wikipedia

    en.wikipedia.org/wiki/Current_loop

    The pressure transmitter modulates the current on the loop to send the signal to the strip chart recorder, but does not in itself supply power to the loop and so is passive. Another loop may contain two passive chart recorders, a passive pressure transmitter, and a 24 V battery (the battery is the active device).