The Sysmex XE-2100 is a haematology automated analyser, used to quickly perform full blood counts and reticulocyte counts. It is made by the Sysmex Corporation. It can be run on its own, or connected to a blood film making and staining unit. Racks of blood go in on a tray on the right, and come out the left side.
A 5-part cell counter can differentiate all WBC types (neutrophils, lymphocytes, basophils, eosinophils, and monocytes). 5-part analyzers are more expensive than 3-part analyzers, but provide more in-depth information about the sample. Specific jobs, such as allergy testing, require 5-part differential analysis. However, most medical tasks can ...
Sysmex Corporation (シスメックス株式会社, Shisumekkusu Kabushiki-gaisha) is a Japanese company headquartered in Kobe that is engaged in the health care business. Originally called TOA Medical Electronics (a branch of the TOA Corporation ), the Sysmex brand was established in 1978, and were mainly involved with haematology analysers.
The white blood cell differential is a common blood test that is often ordered alongside a complete blood count.The test may be performed as part of a routine medical examination; to investigate certain symptoms, particularly those suggestive of infection or hematological disorders; [5] [6] or to monitor existing conditions, such as blood disorders and inflammatory diseases.
Celloscope automated cell counter was developed in the 1950s for enumeration of erythrocytes, leukocytes, and thrombocytes in blood samples. [1] Together with the Coulter counter, the Celloscope analyzer can be considered one of the predecessors of today's automated hematology analyzers, as the principle of the electrical impedance method is still utilized in cell counters installed in ...
Sysmex XT-4000i automated hematology analyzer The Coulter principle—the transient current drop is proportional to the particle volume. To measure the hemoglobin concentration, a reagent chemical is added to the sample to destroy the red cells in a channel separate from that used for red blood cell counts.
Samples used in the analyzers include, but are not limited to, blood, serum, plasma, urine, cerebrospinal fluid, and other fluids from within the body. [4] The design based on separating a continuously flowing stream with air bubbles largely reduced slow, clumsy, and error-prone manual methods of analysis.
[5] Due to its short staining time, Diff-Quik stain is often used for initial screening of cytopathology specimens. This staining technique allows the cytotechnologist or pathologist to quickly assess the adequacy of the specimen, identify possible neoplastic or inflammatory changes, and decide whether or not additional staining is required. [4 ...