  2. Conditional short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Conditional_short-circuit...

    Conditional short-circuit current is the value of the alternating current component of a prospective current, which a switch without integral short-circuit protection, but protected by a suitable short circuit protective device (SCPD) in series, can withstand for the operating time of the current under specified test conditions.

  3. Utilization categories - Wikipedia

    en.wikipedia.org/wiki/Utilization_categories

    Control of small electromagnetic loads with holding current ≤ 0.2 A; e.g. contactor relays 60947-5-2 A: Protection of circuits, with no rated short-time withstand current: 60947-3 B: Protection of circuits, with a rated short-time withstand current: 60947-3 DC-1: Non Inductive or slightly inductive loads, resistance furnaces, heaters: 60947-4 ...

  4. Short-circuit test - Wikipedia

    en.wikipedia.org/wiki/Short-circuit_test

    A different form of short-circuit testing is done to assess the mechanical strength of the transformer windings, and their ability to withstand the high forces produced if an energized transformer experiences a short-circuit fault. Currents during such events can be several times the normal rated current.

  5. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    The effect of too high short-circuit current is discussed in the previous section. The short-circuit current should be around 20 times the rating of the circuit to ensure the branch circuit protection clears a fault quickly. Quick disconnecting is needed, because during a line-to-ground short circuit the grounding pin potential on the power ...

  6. Breaking capacity - Wikipedia

    en.wikipedia.org/wiki/Breaking_capacity

    The prospective short-circuit current that can occur under short circuit conditions should not exceed the rated breaking capacity of the apparatus, otherwise breaking of the current cannot be guaranteed. The current breaking capacity corresponds to a certain voltage, so an electrical apparatus may have more than one breaking capacity current ...

  7. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    In an electric power system, a fault or fault current is any abnormal electric current. For example, a short circuit is a fault in which a live wire touches a neutral or ground wire. An open-circuit fault occurs if a circuit is interrupted by a failure of a current-carrying wire (phase or neutral) or a blown fuse or circuit breaker.

  8. Dielectric withstand test - Wikipedia

    en.wikipedia.org/wiki/Dielectric_withstand_test

    If the current through a device under test is less than a specified limit at the required test potential and time duration, the device meets the dielectric withstand requirement. A dielectric withstand test may be done as a factory test on new equipment, or may be done on apparatus already in service as a routine maintenance test. [2]

  9. List of IEC standards - Wikipedia

    en.wikipedia.org/wiki/List_of_IEC_standards

    IEC 60724 Short-circuit temperature limits of electric cables with rated voltages of 1 kV (U m = 1,2 kV) and 3 kV (U m = 3,6 kV) IEC TR 60725 Consideration of reference impedances and public supply network impedances for use in determining the disturbance characteristics of electrical equipment having a rated current ≤75 A per phase