When.com Web Search

  1. Ads

    related to: multimeter back probe leads

Search results

  1. Results From The WOW.Com Content Network
  2. Multimeter - Wikipedia

    en.wikipedia.org/wiki/Multimeter

    Multimeter test leads. A multimeter can use many different test probes to connect to the circuit or device under test. Crocodile clips, retractable hook clips, and pointed probes are the three most common types. Tweezer probes are used for closely spaced test points, as for instance surface-mount devices. The connectors are attached to flexible ...

  3. Banana connector - Wikipedia

    en.wikipedia.org/wiki/Banana_connector

    In this design, the metal banana plug is entirely sheathed in a plastic tube and inserts into a deeply recessed jack in the multimeter. Alternatively, the equipment may use a deeply recessed male banana plug, while the test lead uses a sheathed banana jack. Additionally, the test lead wire must be made with insulation rated for higher voltages.

  4. Test probe - Wikipedia

    en.wikipedia.org/wiki/Test_probe

    For a typical coaxial cable, loading is of the order of 100pF per meter (the length of a typical test lead). Attenuator probes minimize capacitive loading with an attenuator, but reduce the magnitude of the signal delivered to the instrument. A 10× attenuator will reduce the capacitive load by a factor of about 10.

  5. Multi-tip scanning tunneling microscopy - Wikipedia

    en.wikipedia.org/wiki/Multi-tip_scanning...

    Right: SEM image of a freestanding nanowire contacted by three tips. The STM tips act like the test leads of a multimeter, however, contacting objects like the nanowire at the nanoscale. Movie of an STM tip moving along a GaAs nanowire measuring a four-point probe resistance profile at many points along the nanowire.

  6. Electronic test equipment - Wikipedia

    en.wikipedia.org/wiki/Electronic_test_equipment

    Multimeter e.g., VOM (Volt-Ohm-Milliammeter) or DMM (Digital Multimeter) (Measures all of the above) LCR meter - inductance (L), capacitance (C) and resistance (R) meter (measure LCR values) The following are used for stimulus of the circuit under test: Power supplies; Signal generator; Digital pattern generator; Pulse generator

  7. Four-terminal sensing - Wikipedia

    en.wikipedia.org/wiki/Four-terminal_sensing

    Four-point measurement of resistance between voltage sense connections 2 and 3. Current is supplied via force connections 1 and 4. In electrical engineering, four-terminal sensing (4T sensing), 4-wire sensing, or 4-point probes method is an electrical impedance measuring technique that uses separate pairs of current-carrying and voltage-sensing electrodes to make more accurate measurements ...