When.com Web Search

  1. Ads

    related to: do vrf systems need ductwork cleaning cost service

Search results

  1. Results From The WOW.Com Content Network
  2. Variable refrigerant flow - Wikipedia

    en.wikipedia.org/wiki/Variable_refrigerant_flow

    Variable refrigerant flow (VRF), also known as variable refrigerant volume (VRV), is an HVAC technology invented by Daikin Industries, Ltd. in 1982. [1] Similar to ductless mini-split systems, VRFs use refrigerant as the primary cooling and heating medium, and are usually less complex than conventional chiller-based systems.

  3. Variable air volume - Wikipedia

    en.wikipedia.org/wiki/Variable_air_volume

    Dual duct systems provide cool air in one duct and warm air in a second duct to provide an appropriate temperature of mixed supply air for any zone. An extra duct, however, is cumbersome and expensive. Reheating the air from a single duct, using electric or hot water heating, is often a more cost-effective solution. [12]

  4. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    These motors are sometimes called DC motors, sometimes EC motors and occasionally DC/EC motors. DC stands for direct current and EC stands for electronically commutated.. DC motors allow the speed of the fans within a fan coil unit to be controlled by means of a 0-10 Volt input control signal to the motor/s, the transformers and speed switches associated with AC fan coils are not required.

  5. Run-around coil - Wikipedia

    en.wikipedia.org/wiki/Run-around_coil

    A run-around coil installation, serving air handling units on the roof of an office building. A run-around coil is a type of energy recovery heat exchanger most often positioned within the supply and exhaust air streams of an air handling system, or in the exhaust gases of an industrial process, to recover the heat energy.

  6. Testing, adjusting, balancing - Wikipedia

    en.wikipedia.org/wiki/Testing,_adjusting,_balancing

    In heating, ventilation, and air conditioning (HVAC), testing, adjusting and balancing (TAB) are the three major steps used to achieve proper operation of heating, ventilation, and air conditioning systems. TAB usually refers to commercial building construction and the specialized contractors who employ personnel that perform this service.

  7. Duct (flow) - Wikipedia

    en.wikipedia.org/wiki/Duct_(flow)

    A duct system often begins at an air handler. The blowers in the air handler can create substantial vibration, and the large area of the duct system would transmit this noise and vibration to the inhabitants of the building. To avoid this, vibration isolators (flexible sections) are normally inserted into the duct immediately before and after ...