When.com Web Search

  1. Ad

    related to: 30kw motor full load current computation example

Search results

  1. Results From The WOW.Com Content Network
  2. Utilization factor - Wikipedia

    en.wikipedia.org/wiki/Utilization_factor

    The Load factor is the ratio of the load that a piece of equipment actually draws (time averaged) when it is in operation to the load it could draw (which we call full load). For example, an oversized motor - 15 kW - drives a constant 12 kW load whenever it is on. The motor load factor is then 12/15 = 80%.

  3. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t

  4. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8. Required capacitance per phase if capacitors are connected in delta:

  5. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Load-flow calculation is also the basis of all further network studies, such as motor start-up or investigation of scheduled or unscheduled outages of equipment within the outage simulation. Especially when investigating motor start-up, [ 2 ] the load-flow calculation results give helpful hints, for example, of whether the motor can be started ...

  6. Load factor (electrical) - Wikipedia

    en.wikipedia.org/wiki/Load_factor_(electrical)

    An example, using a large commercial electrical bill: peak demand = 436 kW; use = 57 200 kWh; number of days in billing cycle = 30 d; Hence: load factor = ( [ 57 200 kWh / {30 d × 24 h/d} ] / 436 kW) × 100% = 18.22%; It can be derived from the load profile of the specific device or system of devices. Its value is always less than one because ...

  7. Blocked rotor test - Wikipedia

    en.wikipedia.org/wiki/Blocked_rotor_test

    From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found. It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an ...

  8. Power-flow study - Wikipedia

    en.wikipedia.org/wiki/Power-flow_study

    In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.

  9. Korndörfer autotransformer starter - Wikipedia

    en.wikipedia.org/wiki/Korndörfer_Autotransformer...

    An induction motor draws very high starting current during its acceleration to full rated speed, typically 6 to 10 times the full load current. Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque.