The pacing electrode is advanced through the vein under fluoroscopic and electrocardiographic guidance. An X-ray after the procedure is always obtained to confirm placement of the pacing electrode. The greater use of atropine and epinephrine or external pacing may make transvenous pacing unnecessary by stabilizing patients early in the process ...
Causes of pacemaker failure include lead related failure, unit malfunction, problems at the insertion site, failures related to exposure to high voltage electricity or high intensity microwaves, and a miscellaneous category (one patient had ventricular tachycardia when using his electric razor and another patient had persistent pacing of the ...
If these fail to respond to atropine or there is a potential risk of asystole, transvenous pacing is indicated. The risk factors for asystole include 1) previous asystole, 2) complete heart block with wide complexes, and 3) ventricular pause for > 3 seconds. Mobitz Type 2 AV block is another indication for pacing.
Percussive pacing, also known as transthoracic mechanical pacing, is the use of the closed fist, usually on the left lower edge of the sternum over the right ventricle in the vena cava, striking from a distance of 20 – 30 cm to induce a ventricular beat (the British Journal of Anaesthesia suggests this must be done to raise the ventricular pressure to 10–15 mmHg to induce electrical activity).
Twiddler's syndrome is a malfunction of a pacemaker due to manipulation of the device and the consequent dislodging of the leads from their intended location. As the leads move, they stop pacing the heart and can cause strange symptoms such as phrenic nerve stimulation resulting in abdominal pulsing or brachial plexus stimulation resulting in rhythmic arm twitching. [1]
An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or just pacemaker is an implanted medical device that generates electrical impulses delivered by electrodes to the chambers of the heart either the upper atria, or lower ventricles to cause the targeted chambers to contract and ...
The only suitable cell available at the time was the mercuric oxide-zinc cell, so the battery problems remained. In 1967 Telectronics commenced research into the technologies which could allow hermetic sealing of the pacemaker to preclude water vapour penetration and, as an interim measure contracted AWM a subsidiary of Amalgamated Wireless ...
The difference between pacemakers and ICDs is that pacemakers are also available as temporary units and are generally designed to correct slow heart rates, i.e. bradycardia, while ICDs are often permanent safeguards against sudden life-threatening arrhythmias. S-ICD lead and generator position Sketch of an already-implanted cardioverter ...