When.com Web Search

  1. Ad

    related to: how long does a c tank last on 2 lpm valve box

Search results

  1. Results From The WOW.Com Content Network
  2. Oxygen therapy - Wikipedia

    en.wikipedia.org/wiki/Oxygen_therapy

    A small portable M6 (B) cylinder holds 164 or 170 litres (5.8 or 6.0 cu ft) and weighs about 1.3 to 1.6 kilograms (2.9 to 3.5 lb). [62] These tanks can last 4–6 hours with a conserving regulator, [clarification needed] which adjust flow based on a person's breathing rate. Conserving regulators may not be effective for patients who breathe ...

  3. Oxygen concentrator - Wikipedia

    en.wikipedia.org/wiki/Oxygen_concentrator

    In the first half-cycle, the first cylinder receives air from the compressor, which lasts about 3 seconds. During that time, the pressure in the first cylinder rises from atmospheric to about 2.5 times normal atmospheric pressure (typically 20 psi/138 kPa gauge, or 2.36 atmospheres absolute) and the zeolite becomes saturated with nitrogen.

  4. Portable oxygen concentrator - Wikipedia

    en.wikipedia.org/wiki/Portable_oxygen_concentrator

    Portable oxygen concentrator used with bottle humidifier. POCs operate on the same principle as a home concentrator, pressure swing adsorption. [6] The basic set up of a POC is a miniaturized air compressor, a cylinder filled containing the sieve, a pressure equalizing reservoir and valves and tubes.

  5. Cascade filling system - Wikipedia

    en.wikipedia.org/wiki/Cascade_filling_system

    P 2 and V 2 the initial pressure and volume of the other cylinder and P 3 is the equilibrium pressure. An example could be a 100-litre (internal volume) cylinder (V 1) pressurised to 200 bar (P 1) filling a 10-litre (internal volume) cylinder (V 2) which was unpressurised (P 2 = 1 bar) (resulting in both cylinder equalising to approximately 180 ...

  6. Demand valve oxygen therapy - Wikipedia

    en.wikipedia.org/wiki/Demand_Valve_Oxygen_Therapy

    Demand Valve Oxygen Therapy (DVOT) is a way of delivering high flow oxygen therapy using a device that only delivers oxygen when the patient breathes in and shuts off when they breathe out. DVOT is commonly used to treat conditions such as cluster headache , which affects up to four in 1000 people (0.4%), [ 1 ] [ 2 ] [ 3 ] and is a recommended ...

  7. Mass flow controller - Wikipedia

    en.wikipedia.org/wiki/Mass_flow_controller

    All mass flow controllers have an inlet port, an outlet port, a mass flow sensor and a proportional control valve. The MFC is fitted with a closed loop control system which is given an input signal by the operator (or an external circuit/computer) that it compares to the value from the mass flow sensor and adjusts the proportional valve ...

  8. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    A simplified version of the definition is: The k v factor of a valve indicates "The water flow in m 3 /h, at a pressure drop across the valve of 1 kgf/cm 2 when the valve is completely open. The complete definition also says that the flow medium must have a density of 1000 kg/m 3 and a kinematic viscosity of 10 −6 m 2 /s, e.g. water. [clarify]

  9. Diving cylinder - Wikipedia

    en.wikipedia.org/wiki/Diving_cylinder

    Valve ejected due to mix up with valve threads 3/4"NPSM and 3/4"BSP(F) caused damage to a dive shop compressor room. [92] A valve ejected during filling due to incompatible thread killed the operator by impact to the chest. [38] A valve failed on a diver's emergency cylinder on a diving support vessel during preparation for a dive injuring five ...