  2. Pacemaker crosstalk - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_crosstalk

    Crosstalk can only occur in a dual chamber or biventricular pacemaker. It happens less often in more recent models of dual chamber pacemakers due to the addition of a ventricular blanking period, which coincides with the atrial stimulus. This helps to prevent ventricular channel oversensing of atrial output.

  3. Pacemaker failure - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_failure

    Failure of a pacemaker is defined by the requirement of repeat surgical pacemaker-related procedures after the initial implantation. Most implanted pacemakers are dual chambered and have two leads, causing the implantation time to take longer because of this more complicated pacemaker system.

  4. Sinus node dysfunction - Wikipedia

    en.wikipedia.org/wiki/Sinus_node_dysfunction

    Often sinus node dysfunction produces no symptoms, especially early in the disease course. Signs and symptoms usually appear in more advanced disease and more than 50% of patients will present with syncope or transient near-fainting spells as well as bradycardias that are accompanied by rapid heart rhythms, referred to as tachycardia-bradycardia syndrome [4] [5] Other presenting signs or ...

  5. Artificial cardiac pacemaker - Wikipedia

    en.wikipedia.org/wiki/Artificial_cardiac_pacemaker

    There are three basic types of permanent pacemakers, classified according to the number of chambers involved and their basic operating mechanism: [10] Single-chamber pacemaker. In this type, only one pacing lead is placed into a chamber of the heart, either the atrium or the ventricle. [10] Dual-chamber pacemaker. Here, wires are placed in two ...

  6. Pacemaker syndrome - Wikipedia

    en.wikipedia.org/wiki/Pacemaker_syndrome

    Pacemaker syndrome is a condition that represents the clinical consequences of suboptimal atrioventricular (AV) synchrony or AV dyssynchrony, regardless of the pacing mode, after pacemaker implantation. [1] [2] It is an iatrogenic disease—an adverse effect resulting from medical treatment—that is often underdiagnosed.

  7. Third-degree atrioventricular block - Wikipedia

    en.wikipedia.org/wiki/Third-degree_atrio...

    Third-degree AV block can be treated more permanently with the use of a dual-chamber artificial pacemaker. [16] This type of device typically listens for a pulse from the SA node via lead in the right atrium and sends a pulse via a lead to the right ventricle at an appropriate delay, driving both the right and left ventricles.

  8. Cardiac pacemaker - Wikipedia

    en.wikipedia.org/wiki/Cardiac_pacemaker

    An artificial cardiac pacemaker (or artificial pacemaker, so as not to be confused with the natural cardiac pacemaker) or just pacemaker is an implanted medical device that generates electrical impulses delivered by electrodes to the chambers of the heart either the upper atria, or lower ventricles to cause the targeted chambers to contract and ...

  9. Implantable cardioverter-defibrillator - Wikipedia

    en.wikipedia.org/wiki/Implantable_cardioverter...

    Just like pacemakers, ICDs can have a single wire or lead in the heart (in the right ventricle, single chamber ICD), two leads (in the right atrium and right ventricle, dual chamber ICD) or three leads (biventricular ICD, one in the right atrium, one in the right ventricle and one on the outer wall of the left ventricle).