In electrical circuits, reactance is the opposition presented to alternating current by inductance and capacitance. [1] Along with resistance, it is one of two elements of impedance; however, while both elements involve transfer of electrical energy, no dissipation of electrical energy as heat occurs in reactance; instead, the reactance stores energy until a quarter-cycle later when the energy ...
The state is very brief, as the current in the damper winding quickly decays allowing the armature flux to enter the rotor poles only. The generator goes into transient state; in the transient state (′) the flux is still out of the field winding of the rotor. The transient state decays to steady-state in few cycles. [6]
Foster's reactance theorem is an important theorem in the fields of electrical network analysis and synthesis. The theorem states that the reactance of a passive, lossless two-terminal ( one-port ) network always strictly monotonically increases with frequency.
Alternatively, one can graph the expressions and see where they intersect with the line given by the inverse Damköhler number to see the solution for conversion. In the plot below, the y-axis is the inverse Damköhler number and the x-axis the conversion. The rule-of-thumb inverse Damköhler numbers have been placed as dashed horizontal lines.
In the power systems analysis field of electrical engineering, a per-unit system is the expression of system quantities as fractions of a defined base unit quantity. . Calculations are simplified because quantities expressed as per-unit do not change when they are referred from one side of a transformer to t
An example of the induced current is the current produced in the generator which involves rapidly rotating a coil of wire in a magnetic field. It is a qualitative law that specifies the direction of induced current, but states nothing about its magnitude.
Note, , the reactance in parallel, has a negative reactance because it is typically a capacitor. This gives the L-network the additional feature of harmonic suppression since it is a low pass filter too. The inverse connection (impedance step-up) is simply the reverse—for example, reactance in series with the source.
The siemens (symbol: S) is the unit of electric conductance, electric susceptance, and electric admittance in the International System of Units (SI). Conductance, susceptance, and admittance are the reciprocals of resistance, reactance, and impedance respectively; hence one siemens is equal to the reciprocal of one ohm (Ω −1) and is also referred to as the mho.