For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...
We also see the thick wires in standard colors (two yellow/green ground and two blue neutral), as well as markings PEN (protected earth and neutral), PE (protective earth) and N (neutral). The three bars for the three "live" phases (marked L1, L2 and L3) are also visible on the bottom right.
Some wiring color codes are set by national regulations, but often a color code is specific to a manufacturer or industry. Building wiring under the US National Electrical Code and the Canadian Electrical Code is identified by colors to show energized, neutral, and grounding conductors, and to identify phases. Other color codes are used in the ...
In fixed wiring, the blue/brown scheme is only found in newer (post-2004) installations, and the old IEE red/black scheme is likely to be encountered in existing installations for many more decades. Earlier in the 20th century, green and blue were used as a neutral alongside black, which became the only neutral colour from 1943.
Three-phase systems may have a fourth wire, common in low-voltage distribution. This is the neutral wire. The neutral allows three separate single-phase supplies to be provided at a constant voltage and is commonly used for supplying multiple single-phase loads. The connections are arranged so that, as far as possible in each group, equal power ...
In Sweden there is a notable exception for blue, where while the colour normally is used for neutral, it may be used as connecting wire between switches and between switch and fixture, as well as phase wire in a two-phase circuit, all under the condition that no neutral wire is used in the particular circuit. [11] [12]
A wire or cable has a voltage (to neutral) rating and a maximum conductor surface temperature rating. The amount of current a cable or wire can safely carry depends on the installation conditions. The international standard wire sizes are given in the IEC 60228 standard of the International Electrotechnical Commission .
Center-tapped delta transformer Center-tapped delta transformer voltages. High-leg delta service is supplied in one of two ways. One is by a three-phase transformer (or three single-phase transformers), having four wires coming out of the secondary, the three phases, plus a neutral connected as a center-tap on one of the windings.