  1. Results From The WOW.Com Content Network
  2. Isolated-phase bus - Wikipedia

    en.wikipedia.org/wiki/Isolated-phase_bus

    The consequences of a two- or three-phase fault between the generator and the first circuit breaker are therefore much more serious and often result in severe damage to the busbars and nearby equipment. Isolated-phase bus is made in ratings from 3000 amperes to 45,000 amperes, and rated for voltages from 5000 volts up to about 35,000 volts.

  3. Busbar - Wikipedia

    en.wikipedia.org/wiki/Busbar

    The busbar's material composition and cross-sectional size determine the maximum current it can safely carry. Busbars can have a cross-sectional area of as little as 10 square millimetres (0.016 sq in), but electrical substations may use metal tubes 50 millimetres (2.0 in) in diameter or more as busbars.

  4. Bus duct - Wikipedia

    en.wikipedia.org/wiki/Bus_duct

    In electric power distribution, a bus duct (also called busway) typically uses sheet metal, welded metal [1] or cast resin to contain and isolate copper or aluminium busbars for the purpose of conducting a substantial current of electricity. It is an alternative means of conducting electricity to power cables or cable bus.

  5. Electrical busbar system - Wikipedia

    en.wikipedia.org/wiki/Electrical_busbar_system

    Enclosure comparison with normal wiring & with busbar system. Electrical busbar systems [1] (sometimes simply referred to as busbar systems) are a modular approach to electrical wiring, where instead of a standard cable wiring to every single electrical device, the electrical devices are mounted onto an adapter which is directly fitted to a current carrying busbar.

  6. Bushing (electrical) - Wikipedia

    en.wikipedia.org/wiki/Bushing_(electrical)

    The insulated material between the fixing point and the conductor is the most highly stressed area. The design of any electrical bushing must ensure that the electrical strength of the insulated material is able to withstand the penetrating 'electrical energy' passing through the conductor, via any highly stressed areas.

  7. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...