Search results
Results From The WOW.Com Content Network
In cardiovascular physiology, end-diastolic volume (EDV) is the volume of blood in the right or left ventricle at end of filling in diastole which is amount of blood present in ventricle at the end of diastole. [1]
Wiggers diagram with mechanical (echo), electrical (ECG), and aortic pressure (catheter) waveforms, together with an in-ear dynamic pressure waveform measured using a novel infrasonic hemodynography technology, for a patient with severe aortic stenosis.
Stroke volume (= end-diastolic volume − end-systolic volume) Ejection fraction (= stroke volume / end-diastolic volume) Cardiac output is mathematically ` to systole [clarification needed] Inotropic, chronotropic, and dromotropic states; Cardiac input (= heart rate * suction volume Can be calculated by inverting terms in Fick principle)
where the EDV (end-diastolic volume) is the volume of blood within the ventricle immediately before a contraction and the ESV (end-systolic volume) is the volume of blood remaining in the ventricle at the end of a contraction. The ejection fraction is hence the fraction of the end-diastolic volume that is ejected with each beat. [citation needed]
Diastolic dysfunction is associated with a reduced compliance, or increased stiffness, of the ventricle wall. This reduced compliance results in an inadequate filling of the ventricle and a decrease in the end-diastolic volume. The decreased end-diastolic volume then leads to a reduction in stroke volume because of the Frank-Starling mechanism. [1]
Drawing of the ECG, with labels of intervals. Cardiac electrophysiology is a branch of cardiology and basic science focusing on the electrical activities of the heart.The term is usually used in clinical context, to describe studies of such phenomena by invasive (intracardiac) catheter recording of spontaneous activity as well as of cardiac responses to programmed electrical stimulation ...
Modalities applied to measurement of ejection fraction is an emerging field of medical mathematics and subsequent computational applications. The first common measurement method is echocardiography, [7] [8] although cardiac magnetic resonance imaging (MRI), [8] [9] cardiac computed tomography, [8] [9] ventriculography and nuclear medicine (gated SPECT and radionuclide angiography) [8] [10 ...
The hexaxial reference system is a diagram that is used to determine the heart's electrical axis in the frontal plane. The hexaxial reference system, better known as the Cabrera system, is a convention to present the extremity leads of the 12 lead electrocardiogram, [1] that provides an illustrative logical sequence that helps interpretation of the ECG, especially to determine the heart's ...