When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Recloser - Wikipedia

    en.wikipedia.org/wiki/Recloser

    Controls for the reclosers range from the original electromechanical systems to digital electronics with metering and SCADA functions. The ratings of reclosers run from 2.4–38 kV for load currents from 10–1200 A and fault currents from 1–16 kA. [7] [8] On a 3-phase circuit, a recloser is more beneficial than three separate fuse cutouts.

  3. Single-wire earth return - Wikipedia

    en.wikipedia.org/wiki/Single-wire_earth_return

    Most faults (overcurrent) are transient. Since the network is rural, most of these faults will be cleared by the recloser. Each service site needs a rewirable drop out fuse for protection and switching of the transformer. The transformer secondary should also be protected by a standard high-rupture capacity (HRC) fuse or low voltage circuit ...

  4. Circuit breaker (overcurrent) - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker_(overcurrent)

    Circuit breakers with higher ratings can have adjustable trip settings, allowing fewer standardized products to be used, adjusted to the applicable precise ratings when installed. For example, a circuit breaker with a 400 ampere frame size might have its over-current detection threshold set only 300 amperes where that rating is appropriate.

  5. Intelligent electronic device - Wikipedia

    en.wikipedia.org/wiki/Intelligent_electronic_device

    Protective relay is an example of an intelligent electronic device. In the electric power industry, an intelligent electronic device (IED) is an integrated microprocessor-based controller of power system equipment, such as circuit breakers, transformers and capacitor banks. [1]

  6. Talk:Recloser - Wikipedia

    en.wikipedia.org/wiki/Talk:Recloser

    While the recloser does in fact help to break up distribution circuits into smaller, more manageable pieces, many protection schemes involving circuit breakers in distribution substations also apply reclosing to some extent, thus not "blacking out" the circuit and requiring a crew go to the station and reset a lockout.

  7. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  8. Vacuum interrupter - Wikipedia

    en.wikipedia.org/wiki/Vacuum_interrupter

    In 1956, Hugh C. Ross at Jennings Radio Manufacturing Corporation revolutionized the high-frequency-circuit vacuum switch and produced a vacuum switch with a rating of 15 kV at 200 A. Five years later, Thomas H. Lee at General Electric produced the first vacuum circuit breakers [2] [3] with a rated voltage of 15 kV at short-circuit breaking ...

  9. Transfer switch - Wikipedia

    en.wikipedia.org/wiki/Transfer_switch

    One example is an open transition automatic transfer switch (ATS). During the split second of the power transfer the flow of electricity is interrupted. Another example is a manual three position switch or circuit breaker, with utility power on one side, the generator on the other, and "off" in the middle, which requires the user to switch ...