When.com Web Search

  1. Ads

    related to: 12 eer air conditioner rating plate diagram

Search results

  1. Results From The WOW.Com Content Network
  2. Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Seasonal_energy_efficiency...

    In the United States, the efficiency of air conditioners is often rated by the seasonal energy efficiency ratio (SEER) which is defined by the Air Conditioning, Heating, and Refrigeration Institute, a trade association, in its 2008 standard AHRI 210/240, Performance Rating of Unitary Air-Conditioning and Air-Source Heat Pump Equipment. [1]

  3. European seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/European_seasonal_energy...

    In Europe, the seasonal efficiency of refrigeration equipment, chillers and air conditioners is often rated by the European seasonal energy efficiency ratio (ESEER) which is controlled (among others) by the Eurovent Certification Company. [1] A similar standard in the United States is the integrated energy efficiency ratio (IEER).

  4. European Union energy label - Wikipedia

    en.wikipedia.org/wiki/European_Union_energy_label

    For air conditioners, the directive applies only to units under 12 kW. Every label contains the following information: the model, the energy efficiency category from A+++ to G, the annual energy consumption (full load at 500 hours per year) the cooling output at full load in kW

  5. Minimum energy performance standard - Wikipedia

    en.wikipedia.org/wiki/Minimum_energy_performance...

    Almost all of its standards are joint standards with Australia. New Zealand has mandatory Energy rating labelling for dishwashers and clothes dryers, fridges, washing machines and room air conditioners. MEPS apply to the following: [6] Refrigerators and freezers; Washing machines; Air conditioners; Computer room air conditioners; Chillers

  6. Coefficient of performance - Wikipedia

    en.wikipedia.org/wiki/Coefficient_of_performance

    The coefficient of performance or COP (sometimes CP or CoP) of a heat pump, refrigerator or air conditioning system is a ratio of useful heating or cooling provided to work (energy) required. [1] [2] Higher COPs equate to higher efficiency, lower energy (power) consumption and thus lower operating costs. The COP is used in thermodynamics.

  7. Heating seasonal performance factor - Wikipedia

    en.wikipedia.org/wiki/Heating_seasonal...

    HSPF is specifically used to measure the efficiency of air source heat pumps. HSPF is defined as the ratio of heat output (measured in BTUs) over the heating season to electricity used (measured in watt-hours). [1] [2] It therefore has units of BTU/watt-hr. The higher the HSPF rating of a unit, the more energy efficient it is.

  8. Talk:Seasonal energy efficiency ratio - Wikipedia

    en.wikipedia.org/wiki/Talk:Seasonal_energy...

    Every air conditioning system when evaluated by the test procedures for SEER and EER will provide some hopefully repeatable number. For that air conditioning system, these two ratings will have some ratio to each other. Accordingly, that ratio is fixed only by the SEER rating and the EER rating and is not affected by where the system is installed.

  9. House Energy Rating - Wikipedia

    en.wikipedia.org/wiki/House_energy_rating

    The rating level of buildings is determined in three parameters; Basic Items: refers to the regulated energy use per square meter, obtained by computer modeling or measurements. Required Items: refers to minimum performance requirements for building envelope and Heating Ventilation and Air-Conditioning (HVAC).