When.com Web Search

  1. Ad

    related to: unbalanced load neutral calculation tool excel sample

Search results

  1. Results From The WOW.Com Content Network
  2. Mathematics of three-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Mathematics_of_three-phase...

    An unbalanced system is analysed as the superposition of three balanced systems, each with the positive, negative or zero sequence of balanced voltages. When specifying wiring sizes in a three-phase system, we only need to know the magnitude of the phase and neutral currents.

  3. Load balancing (electrical power) - Wikipedia

    en.wikipedia.org/wiki/Load_balancing_(electrical...

    Load balancing, load matching, or daily peak demand reserve refers to the use of various techniques by electrical power stations to store excess electrical power during low demand periods for release as demand rises. [1] The aim is for the power supply system to have a load factor of 1.

  4. Balancing of rotating masses - Wikipedia

    en.wikipedia.org/wiki/Balancing_of_rotating_masses

    The system rotates without requiring the application of any external force or couple, other than that required to support its weight. If a system is initially unbalanced, to avoid the stress upon the bearings caused by the centrifugal couple, counterbalancing weights must be added. This is seen when a bicycle wheel gets a buckled rim.

  5. Power system simulation - Wikipedia

    en.wikipedia.org/wiki/Power_system_simulation

    Load-flow calculation is also the basis of all further network studies, such as motor start-up or investigation of scheduled or unscheduled outages of equipment within the outage simulation. Especially when investigating motor start-up, [ 2 ] the load-flow calculation results give helpful hints, for example, of whether the motor can be started ...

  6. Ground and neutral - Wikipedia

    en.wikipedia.org/wiki/Ground_and_neutral

    The neutral carries current if the loads on each phase are not identical. In some jurisdictions, the neutral is allowed to be reduced in size if no unbalanced current flow is expected. If the neutral is smaller than the phase conductors, it can be overloaded if a large unbalanced load occurs.

  7. Delta-wye transformer - Wikipedia

    en.wikipedia.org/wiki/Delta-wye_transformer

    An example would be a distribution transformer with a delta primary, running on three 11 kV phases with no neutral or earth required, and a star (or wye) secondary providing a 3-phase supply at 415 V, with the domestic voltage of 240 available between each phase and the earthed (grounded) neutral point.

  8. Engine balance - Wikipedia

    en.wikipedia.org/wiki/Engine_balance

    The shape could be enclosed in a 5 ⁄ 8-inch square for one of the unbalanced locomotives and was reduced to a point when weights were added to counter revolving and reciprocating masses. [12] The effect of vertical out-of-balance, or varying wheel load on the rail, was quantified by Professor Robinson in the U.S. in 1895.

  9. Unit commitment problem in electrical power production

    en.wikipedia.org/wiki/Unit_Commitment_Problem_in...

    generation is distributed across a vast geographical area (e.g., a country), and therefore the response of the electrical grid, itself a highly complex system, has to be taken into account: even if the production levels of all units are known, checking whether the load can be sustained and what the losses are requires highly complex power flow ...