Search results
Results From The WOW.Com Content Network
Therapeutic doses of radiation therapy are often given and tolerated well even at higher doses to treat discrete, well-defined anatomical structures. The same dose given over a longer period of time is less likely to cause ARS. Dose thresholds are about 50% higher for dose rates of 20 rad/h, and even higher for lower dose rates. [4]
Effective dose is a dose quantity in the International Commission on Radiological Protection (ICRP) system of radiological protection. [1]It is the tissue-weighted sum of the equivalent doses in all specified tissues and organs of the human body and represents the stochastic health risk to the whole body, which is the probability of cancer induction and genetic effects, of low levels of ...
Dose and dose rate are used to measure different quantities [1] in the same way that distance and speed are used to measure different quantities. When considering stochastic radiation effects, only the total dose is relevant; each incremental unit of dose increases the probability that the stochastic effect happens. [ 4 ]
CDE is defined by the United States Nuclear Regulatory Commission in Title 10, Section 20.1003, of the Code of Federal Regulations (10 CFR 20.1003), such that "The Committed dose equivalent, CDE (H T,50) is the dose to some specific organ or tissue of reference (T) that will be received from an intake of radioactive material by an individual during the 50-year period following the intake".
1 × 10 ^ 0: Annual: 0.11: Limit of dose from man-made sources to a member of the public who is not a radiation worker in the US and Canada [6] [9] 1.1 1.1 × 10 ^ 0: Annual: 0.13: Average USA radiation worker occupational dose in 1980 [6] 1.2 1.2 × 10 ^ 0: Acute-Abdominal X-ray [7] 2 2 × 10 ^ 0: Annual: 0.23: USA average medical and natural ...
The deterministic effects that can lead to acute radiation syndrome only occur in the case of high doses (> ~10 rad or > 0.1 Gy) and high dose rates (> ~10 rad/h or > 0.1 Gy/h). A model of deterministic risk would require different weighting factors (not yet established) than are used in the calculation of equivalent and effective dose.
Radiation dosimetry in the fields of health physics and radiation protection is the measurement, calculation and assessment of the ionizing radiation dose absorbed by an object, usually the human body. This applies both internally, due to ingested or inhaled radioactive substances, or externally due to irradiation by sources of radiation.
The ICRP 2007 standard values for relative effectiveness are given below. The higher radiation weighting factor for a type of radiation, the more damaging it is, and this is incorporated into the calculation to convert from gray to sievert units. The radiation weighting factor for neutrons has been revised over time and remains controversial.