Search results
Results From The WOW.Com Content Network
A calibration curve plot showing limit of detection (LOD), limit of quantification (LOQ), dynamic range, and limit of linearity (LOL).. In analytical chemistry, a calibration curve, also known as a standard curve, is a general method for determining the concentration of a substance in an unknown sample by comparing the unknown to a set of standard samples of known concentration. [1]
Figure FHN: To mimick the action potential, the FitzHugh–Nagumo model and its relatives use a function g(V) with negative differential resistance (a negative slope on the I vs. V plot). For comparison, a normal resistor would have a positive slope, by Ohm's law I = GV, where the conductance G is the inverse of resistance G=1/R.
The Hodgkin–Huxley model, or conductance-based model, is a mathematical model that describes how action potentials in neurons are initiated and propagated. It is a set of nonlinear differential equations that approximates the electrical engineering characteristics of excitable cells such as neurons and muscle cells .
The FitzHugh–Nagumo model (FHN) describes a prototype of an excitable system (e.g., a neuron). It is an example of a relaxation oscillator because, if the external stimulus I ext {\displaystyle I_{\text{ext}}} exceeds a certain threshold value, the system will exhibit a characteristic excursion in phase space , before the variables v ...
Siméon Denis Poisson. Poisson's equation is an elliptic partial differential equation of broad utility in theoretical physics.For example, the solution to Poisson's equation is the potential field caused by a given electric charge or mass density distribution; with the potential field known, one can then calculate the corresponding electrostatic or gravitational (force) field.
Tafel plot for an anodic process (). The Tafel equation is an equation in electrochemical kinetics relating the rate of an electrochemical reaction to the overpotential. [1] The Tafel equation was first deduced experimentally and was later shown to have a theoretical justification.
The action potential pulse is a model of the speed an action potential that is dynamically dependent upon the position and number of ion channels, and the shape and make up of the axon. The action potential pulse model takes into account entropy and the conduction speed of the action potential along an axon.
The Goldman–Hodgkin–Katz flux equation (or GHK flux equation or GHK current density equation) describes the ionic flux across a cell membrane as a function of the transmembrane potential and the concentrations of the ion inside and outside of the cell.