When.com Web Search

  1. Ads

    related to: transformer rewinding near me current

Search results

  1. Results From The WOW.Com Content Network
  2. Autotransformer - Wikipedia

    en.wikipedia.org/wiki/Autotransformer

    For a step-up transformer, the subscripts in the above equations are reversed where, in this situation, and are greater than and , respectively. As in a two-winding transformer, the ratio of secondary to primary voltages is equal to the ratio of the number of turns of the winding they connect to.

  3. Transformer types - Wikipedia

    en.wikipedia.org/wiki/Transformer_types

    A current transformer (CT) is a series connected measurement device designed to provide a current in its secondary coil proportional to the current flowing in its primary. Current transformers are commonly used in metering and protective relays in the electrical power industry.

  4. Coil winding technology - Wikipedia

    en.wikipedia.org/wiki/Coil_winding_technology

    A rotor makes a complete rotation in 360 degrees. That amounts to 180 degrees to pass by each pole of a two pole machine. The current in conductors also goes through a complete cycle in 360 degrees. For a four pole machine, each pole spans only 90 degrees. During the 90 degrees the current in a conductor goes through a half cycle, or 180 degrees.

  5. Zigzag transformer - Wikipedia

    en.wikipedia.org/wiki/Zigzag_transformer

    If one or more phases fault to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is I a0 = I b0 = I c0.) Zero-sequence (earth fault) current exists between the transformer’s neutral to the faulting phase.

  6. Armature (electrical) - Wikipedia

    en.wikipedia.org/wiki/Armature_(electrical)

    In electrical engineering, the armature is the winding (or set of windings) of an electric machine which carries alternating current. [1] The armature windings conduct AC even on DC machines, due to the commutator action (which periodically reverses current direction) or due to electronic commutation, as in brushless DC motors.

  7. Tap changer - Wikipedia

    en.wikipedia.org/wiki/Tap_changer

    This is a relatively recent development which uses thyristors both to switch the transformer winding taps and to pass the load current in the steady state. The disadvantage is that all non-conducting thyristors connected to the unselected taps still dissipate power due to their leakage currents and they have limited short circuit tolerance.

  1. Ads

    related to: transformer rewinding near me current