A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or current flowing to another powered conductor.
To eliminate this confusion, the IEC decided to apply the term residual current device (RCD) to differential-current-operated ELCBs. Residual current refers to any residue when comparing current in the outbound and return currents in the circuit. In a single phase circuit this is simply the live or phase current minus the neutral current.
GTO thyristors suffer from long switch-off times, whereby after the forward current falls, there is a long tail time where residual current continues to flow until all remaining charge from the device is taken away. This restricts the maximum switching frequency to about 1 kHz. It may be noted, however, that the turn-off time of a GTO is ...
When current flows from a line conductor to an earth wire, as is the case when a line conductor makes contact with an earthed surface in a Class I appliance, an automatic disconnection of supply (ADS) device such as a circuit breaker or a residual-current device (RCD) will automatically open the circuit to clear the fault.
In power engineering, the power-flow study, or load-flow study, is a numerical analysis of the flow of electric power in an interconnected system. A power-flow study usually uses simplified notations such as a one-line diagram and per-unit system, and focuses on various aspects of AC power parameters, such as Voltage, voltage angles, real power and reactive power.
To provide supplementary protection against high-impedance faults it is common to recommend a residual-current device (RCD) also known as a residual current circuit breaker (RCCB), ground fault circuit interrupter (GFCI), or residual current operated circuit-breaker with integral over-current protection (RCBO), which will cut off the supply of ...
Busy is in it for 1951 a residual current circuit breaker of the company protection devices Society & Co. mbH. KG, Schalksmuehle / Westphalia. (Schupa) with the trade name cobweb , [26] which was designed in two-, three-and four-pole version for a nominal current of 25 A and voltages up to 380 V with a tripping fault current of 0.3A.
Electrical equipment may be designed with a floating ground for one of several reasons. One is safety. For example, a low-voltage DC power supply, such as a mobile phone charger, is connected to the mains through a transformer of one type or another, and there is no direct electrical connection between the current return path on the low-voltage side and physical ground (earth).