The minimum bend radius is in general also a function of tensile stresses, e.g., during installation, while being bent around a sheave while the fiber or cable is under tension. If no minimum bend radius is specified, one is usually safe in assuming a minimum long-term low-stress radius not less than 15 times the cable diameter, or 2 inches. [1]
Eliminating multi-layers guarantees a uniform bend radius across each conductor. At any point where the cable flexes, the path of any core moves quickly from the inside to the outside of the cable. The result is that no single core compresses near the inside of the bend or stretches near the outside of the bend—which reduces overall stresses.
Category 6 and 6A cable must be properly installed and terminated to meet specifications. The cable must not be kinked or bent too tightly; the bend radius should be larger than four times the outer diameter of the cable. [16] The wire pairs must not be untwisted and the outer jacket must not be stripped back more than 13 mm (0.51 in).
In past, cable trams or funiculars only as hills too steep for horses. [1] Currently used by unassisted electric trams. 1 in 8.6 (11.6%) Pöstlingbergbahn, Austria: 1898: 1 in 9 (11.1%) Cass Scenic Railway, West Virginia, United States: 1901: Former logging railway, steepest non-electrified adhesion railway 1 in 9 (11%) or 1 in 10 (10%)
Ropes used for suspension are often called cables. [16] Track ropes (full locked ropes) have to act as rails for the rollers of cabins or other loads in aerial ropeways and cable cranes. In contrast to running ropes, track ropes do not take on the curvature of the rollers. Under the roller force, a so-called free bending radius of the rope occurs.
Some cable protection systems include a polymer based vertebrae system which restricts the bend radius to a maximum of a few degrees per segment. These systems are lighter (in water) than their metal equivalents and often more expensive to produce but must be carefully assessed for longevity in the proposed application.
Special tube bending equipment is used to bend the conduit without kinking or denting it. The cost of conduit installation is higher than other wiring methods due to the cost of materials and labor. In applications such as residential construction, the high degree of physical damage protection may not be required, so the expense of conduit is ...
The inner diameter measures 9 μm for single-mode cables, and 50 / 62.5 μm for multi-mode cables. The development of "reduced bend radius" fiber in the mid-2000s, enabled a trend towards smaller cables. Each unit of diameter reduction in a round cable, produces a disproportionate corresponding reduction in the space the cable occupies. [1]