A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...
A receptacle tester for North American wiring An electrical outlet tester , receptacle tester , or socket tester is a small device containing a 3-prong power plug and three indicator lights, used for quickly detecting some types of incorrectly-wired electrical wall outlets or campsite supplies.
A 3-way lamp, also known as a tri-light, is a lamp that uses a 3-way light bulb to produce three levels of light in a low-medium-high configuration. A 3-way lamp requires a 3-way bulb and socket, and a 3-way switch. In 3-way incandescent light bulbs, each of the filaments operates at full voltage. Lamp bulbs with dual carbon filaments were ...
The "California 3-way" or "Coast 3-way" connection never connects the lamp socket shell to the line (hot) terminal. An optional additional lamp can be connected at Terminal A as a pilot lamp, or to illuminate a long corridor. An optional receptacle can be connected at Terminal B, since that terminal is always live.
Plus the average GFCI receptacle costs about an hour's wages - or less. One GFCI receptacle can be used to protect a number of donwstream receptacles, if you're building a summer cottage or a doghouse or something and want to save $8 or so. And if you need to protect a permanently-wired apparatus, you can of course buy a GFCI circuit breaker.
As of the 2020 NEC this exception no longer exists and those devices in are required to have GFCI protection where otherwise required. Two-wire outlets having no grounding conductor may be protected by a GFCI or one upstream of the receptacle and must be labelled "No Equipment Ground" and "GFCI Protected". Most GFCI receptacles allow the ...
Such devices may be found in the form of either a circuit breaker, known as an earth-leakage circuit breaker (ELCB), or built into a socket (aka receptacle). Voltage-operated ELCBs can still be found in the wild, though these largely fell out of favour after the invention of the current-sensing based RCD (aka GFCI) technology.
The NEC also permits grounding-type receptacles in non-grounded wiring protected by a GFCI; this only applies when old non-grounded receptacles are replaced with grounded receptacles, and the new receptacles must be marked with 'No equipment ground' and 'GFCI Protected' . 240 V receptacle faces