Once access to the jugular vein is confirmed, a guidewire and introducer sheath are typically placed to facilitate the shunt's placement. This enables the interventional radiologist to gain access to the patient's hepatic vein by traveling from the superior vena cava into the inferior vena cava and finally the hepatic vein.
A round-tipped guidewire is then advanced through the lumen of the needle, and the needle is withdrawn. A sheath or blunt cannula can now be passed over the guidewire into the cavity or vessel. Alternatively, drainage tubes are passed over the guidewire (as in chest drains or nephrostomies). After passing a sheath or tube, the guidewire is ...
Bougie over guidewire dilators are used at the time of gastroscopy or fluoroscopy. An endoscopy is usually performed first to evaluate the anatomy, and a guidewire is passed into the stomach past the obstruction. This may also be done fluoroscopically. Bougies are again introduced—this time over the guidewire—in sequentially increasing sizes.
The drainage catheter is then removed over the guidewire and sheath is inserted into the ducts (7 to 8 French size). Contrast is then injected through the sheath to identify any stones or strictures. If a stricture is identified, put in biliary manipulation catheter with guidewire measuring 0.035 inches and commence balloon dilatation (with ...
Peel-off sheath was then inserted over the guidewire. Blood is aspirated from the catheter to confirm the position. Then, the free-end of the port catheter is inserted through the peel-off sheath. After the tip of the port catheter is confirmed at the aortocaval junction, the peel-off sheath is taken-off by peeling away with two hands.
The needle is then exchanged for an "introducer sheath" which is a small tube that is advanced over the introducer guide wire and into the blood vessel. The introducer guide wire is removed, and exchanged for a catheter or other medical device to be used to deliver medication or implantation of a medical implant such as a filter or a stent into ...
Most guide wires have a light on the tip which may produce light transmission seen through the skin to help the physician with correct placement of the guide wire. Once access to a blocked sinus is confirmed, a balloon catheter is advanced over the guide wire and positioned in the blocked sinus opening for inflation. The balloon is inflated.
Once the catheter is in and all preparations are complete elsewhere in the lab, the EP study begins. The X-ray machine will give the doctor a live view of the heart and the position of the electrodes. He will guide the (steerable) electrodes to the correct position inside the heart.