Search results
Results From The WOW.Com Content Network
For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...
Here are the conversion factors for those various expressions of wind speed: 1 m/s = 2.237 statute mile/h = 1.944 knots 1 knot = 1.151 statute mile/h = 0.514 m/s 1 statute mile/h = 0.869 knots = 0.447 m/s. Note: 1 statute mile = 5,280 feet = 1,609 meters
With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...
atm cfm [citation needed] ≡ 1 atm × 1 cu ft/min = 47.820 074 682 24 W: atmosphere-cubic foot per second: atm cfs [citation needed] ≡ 1 atm × 1 cu ft/s = 2.869 204 480 9344 × 10 3 W: BTU (International Table) per hour: BTU IT /h ≡ 1 BTU IT /h ≈ 0.293 071 W: BTU (International Table) per minute: BTU IT /min ≡ 1 BTU IT /min ≈ 17.584 ...
Oil conversion factor from m³ to bbl (or stb) is 6.28981100 Gas conversion factor from standard m³ to scf is 35.314666721 Note that the m³ gas conversion factor takes into account a difference in the standard temperature base for measurement of gas volumes in metric and imperial units.
The area required to calculate the volumetric flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface. The vector area is a combination of the magnitude of the area through which the volume passes through, A , and a unit vector normal to the area, n ^ {\displaystyle {\hat {\mathbf {n} }}} .
The area required to calculate the mass flow rate is real or imaginary, flat or curved, either as a cross-sectional area or a surface, e.g. for substances passing through a filter or a membrane, the real surface is the (generally curved) surface area of the filter, macroscopically - ignoring the area spanned by the holes in the filter/membrane ...
Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.