When.com Web Search

  1. Ads

    related to: difference between r1a and r1b water supply fittings for plumbing

Search results

  1. Results From The WOW.Com Content Network
  2. Street elbow - Wikipedia

    en.wikipedia.org/wiki/Street_elbow

    Street elbows are available with bend angles of 90°, 45°, and 22.5°. They can be used in many plumbing applications, including water supply, drainage, sewers, vents, central vacuum systems, compressed air and gas lines, heating and air conditioning, sump pump drains, and other locations where plumbing fittings would be used to join sections of pipe.

  3. Piping and plumbing fitting - Wikipedia

    en.wikipedia.org/wiki/Piping_and_plumbing_fitting

    It must be installed in an easily accessible place for adjustment, replacement, and repair. A trap primer, a specialized valve, is usually connected to a clean-water supply in addition to a DWV system. [20] Because of the dual connection, it must be designed to resist the accidental backflow of contaminated water.

  4. Drain-waste-vent system - Wikipedia

    en.wikipedia.org/wiki/Drain-waste-vent_system

    A sewer pipe is normally at neutral air pressure compared to the surrounding atmosphere.When a column of waste water flows through a pipe, it compresses air ahead of it in the system, creating a positive pressure that must be released so it does not push back on the waste stream and downstream traps, slow drainage, and induce potential clogs.

  5. Plumbing fixture - Wikipedia

    en.wikipedia.org/wiki/Plumbing_fixture

    Each fixture usually has a characteristic means of connection. Normal plumbing practice is to install a valve on each water supply line before the fixture, and this is most commonly termed a stop or "service valve". The water supply to some fixtures is cold water only (such as water closets and urinals). Most fixtures also have a hot water supply.

  6. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  7. Standpipe (firefighting) - Wikipedia

    en.wikipedia.org/wiki/Standpipe_(firefighting)

    External access point for fire sprinkler and dry standpipe at a building in San Francisco, US Antique wet standpipe preserved at Edison and Ford Winter Estates. A standpipe or riser is a type of rigid water piping which is built into multi-story buildings in a vertical position, or into bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water ...