  1. Results From The WOW.Com Content Network
  2. Mains electricity - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity

    The United States and Canada use a supply voltage of 120 volts ± 6%. Japan, Taiwan, Saudi Arabia, North America, Central America and some parts of northern South America use a voltage between 100 V and 127 V. However, most of the households in Japan equip split-phase electric power like the United States, which can supply 200 V by using ...

  3. Mains electricity by country - Wikipedia

    en.wikipedia.org/wiki/Mains_electricity_by_country

    For example, in North America, a unique split-phase system is used to supply to most premises that works by center tapping a 240 volt transformer. This system is able to concurrently provide 240 volts and 120 volts. Consequently, this allows homeowners to wire up both 240 V and 120 V circuits as they wish (as regulated by local building codes).

  4. Split-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Split-phase_electric_power

    However, 130/225 V, three-wire, two-phase electric power discontinued systems called B1 are used to run old installations in small groups of houses when only two of the three-phase high-voltage conductors are used. The phase shift in Europe is 120°, as is the case with three-phase current. That's why we calculate 130V * √3 = 225V.

  5. Voltage converter - Wikipedia

    en.wikipedia.org/wiki/Voltage_converter

    A simple voltage dropper can be used to reduce the voltage for low-power devices; if more than 12V is required, or for high-powered devices, a switched-mode power supply is used. The output will usually be DC in the range 1.5–24 V. Power supplies that output either 100–120 V AC or 210–240 V AC are available; they are called inverters ...

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    The most common three-phase system will have three hot legs, 208 V to each other and 120 V each to the neutral. An older, but still widely used, high-leg delta system uses three phases with 240 volts phase-to-phase for motor loads, and 120 volts for lighting loads by use of a center-tapped transformer; two of the phases are 120 volts to neutral ...

  7. IEC 60038 - Wikipedia

    en.wikipedia.org/wiki/IEC_60038

    Where two voltages are given below separated by "/", the first is the root-mean-square voltage between a phase and the neutral connector, whereas the second is the corresponding root-mean-square voltage between two phases (exception: the category shown below called "One Phase", where 240 V is the root-mean-square voltage between the two legs of a split phase).

  8. Single-phase electric power - Wikipedia

    en.wikipedia.org/wiki/Single-phase_electric_power

    These two give different voltages from a given supply. For example, on a 120/208 three-phase system, which is common in North America, the phase-to-neutral voltage is 120 volts and the phase-to-phase voltage is 208 volts. This allows single-phase lighting to be connected phase-to-neutral.

  9. Volt - Wikipedia

    en.wikipedia.org/wiki/Volt

    The volt (symbol: V) is the unit of electric potential, electric potential difference ... 120 V in North America; 230 V in Europe, Asia, Africa and Australia;