When.com Web Search

  1. Ads

    related to: install gfci outlet with switch 2 black wires and a blue line flag background

Search results

  1. Results From The WOW.Com Content Network
  2. Bootleg ground - Wikipedia

    en.wikipedia.org/wiki/Bootleg_ground

    A receptacle with a bootleg ground. In building wiring installed with separate neutral and protective ground bonding conductors (a TN-S network), a bootleg ground (or a false ground) is a connection between the neutral side of a receptacle or light fixture and the ground lug or enclosure of the wiring device.

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage protection device, that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating leakage current to ground or ...

  4. Three-prong adaptor - Wikipedia

    en.wikipedia.org/wiki/Three-prong_adaptor

    The grounding wire would be diverted around the adapter to reach the faceplate screw above it. However, this ground-wire style of cheater plug was discontinued when it was noted that a loose unattached grounding wire could accidentally become connected to the "hot" blade of a nearby outlet, potentially leading to electric shock. As an ...

  5. NEMA connector - Wikipedia

    en.wikipedia.org/wiki/NEMA_connector

    NEMA 1-15P (two-pole, no ground) and NEMA 5-15P (two-pole with ground pin) plugs are used on common domestic electrical equipment, and NEMA 5-15R is the standard 15-ampere electric receptacle (outlet) found in the United States, and under relevant national standards, in Canada (CSA C22.2 No. 42 [1]), Mexico (NMX-J-163-ANCE) and Japan (JIS C 8303).

  6. Electrical wiring in North America - Wikipedia

    en.wikipedia.org/wiki/Electrical_wiring_in_North...

    For power circuits, the color-coding uses the same colors as residential construction, and adds the additional wires used for three-phase systems. Black, Red and Blue are used for hot wires and White is used as the neutral wire in a 120/208 V circuit. Brown, Orange and Yellow are used as hot wires and gray is used as the neutral wire in a 277/ ...

  7. Earth-leakage protection device - Wikipedia

    en.wikipedia.org/wiki/Earth-leakage_circuit_breaker

    A wire break in the fault to load section, or in the earth to ground section, will disable operation of the devices. Requirement of an additional third wire from the load to the devices. Separate devices cannot be grounded individually. Any additional connection to Earth on the protected system can disable the detector.

  8. Industrial and multiphase power plugs and sockets - Wikipedia

    en.wikipedia.org/wiki/Industrial_and_multiphase...

    A plug is defined in IEC 60050 as an accessory having pins designed to engage with the contacts of a socket-outlet, also incorporating means for the electrical connection and mechanical retention of flexible cables or cords, a plug does not contain components which modify the electrical output from the electrical input (except where a switch or ...

  9. Multiway switching - Wikipedia

    en.wikipedia.org/wiki/Multiway_switching

    In building wiring, multiway switching is the interconnection of two or more electrical switches to control an electrical load from more than one location.A common application is in lighting, where it allows the control of lamps from multiple locations, for example in a hallway, stairwell, or large room.

  1. Related searches install gfci outlet with switch 2 black wires and a blue line flag background

    gfci receptacle protectiongfci equipment protection device