Search results
Results From The WOW.Com Content Network
The French scale measures the outer diameter of the catheter, not the size of the internal drainage channel (inner diameter). For instance, a two-way catheter of 20 Fr and a three-way catheter of 20 Fr have the same outer diameter, but the three-way catheter has an additional channel for irrigation, reducing the size of its drainage channel.
Clark's rule is a medical term referring to a mathematical formula used to calculate the proper dosage of medicine for children aged 2–17 based on the weight of the patient and the appropriate adult dose. [1] The formula was named after Cecil Belfield Clarke (1894–1970), a Barbadian physician who practiced throughout the UK, the West Indies ...
This article consists of tables outlining a number of physical quantities.. The first table lists the fundamental quantities used in the International System of Units to define the physical dimension of physical quantities for dimensional analysis.
The Pediatric Assessment Triangle or PAT is a tool used in emergency medicine to form a general impression of a pediatric patient. [1] In emergency medicine, a general impression is formed the first time the medical professional views the patient, usually within seconds. [ 2 ]
The re-usable models can be autoclaved up to 50 times, while the modified laryngeal tube (Suction) incorporates an extra lumen for inserting a gastric tube or suction system. There are six sizes of the laryngeal tube, ranging from newborn (size 0) to large adult (size 5). The connector of the tube is color-coded for each size.
Due to natural variation, individuals pass through the Tanner stages at different rates, depending in particular on the timing of puberty.Among researchers who study puberty, the Tanner scale is commonly considered the "gold standard" for assessing pubertal status when it is conducted by a trained medical examiner. [5]
The Combitube's ease of use makes it an option for use in the pre-hospital, emergency setting when advanced level providers capable of placing an endotracheal tube are not immediately available. The drawbacks of Combitubes are evidenced by reports of serious complications such as aspiration, esophagus perforation [ 3 ] and cranial nerve ...
Pulmonary compliance is calculated using the following equation, where ΔV is the change in volume, and ΔP is the change in pleural pressure: = For example, if a patient inhales 500 mL of air from a spirometer with an intrapleural pressure before inspiration of −5 cm H 2 O and −10 cm H 2 O at the end of inspiration.