When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Eurocode 2: Design of concrete structures - Wikipedia

    en.wikipedia.org/wiki/Eurocode_2:_Design_of...

    Providing not less than the minimum permitted percentage of reinforcement. Limiting the spacing of tension reinforcement. Using “deemed to satisfy” empirical methods. If actual deflections are required, then the structure must be analysed for the serviceability limit state, using design service loads.

  3. Crack spacing of reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Crack_spacing_of...

    The above CEB expression was intended to calculate crack spacings on the surface of the member. Crack spacings become larger as the distance from the reinforcement increases. For this case, it is suggested to use the maximum distance from the reinforcement, instead of cover distance c (Collins & Mitchell).

  4. Concrete slab - Wikipedia

    en.wikipedia.org/wiki/Concrete_slab

    Steel-reinforced slabs, typically between 100 and 500 mm thick, are most often used to construct floors and ceilings, while thinner mud slabs may be used for exterior paving (see below). [1] [2] In many domestic and industrial buildings, a thick concrete slab supported on foundations or directly on the subsoil, is

  5. Waffle slab foundation - Wikipedia

    en.wikipedia.org/wiki/Waffle_slab_foundation

    Waffle slab foundations adhere to International Building Code requirements. By 2008, most states put into effect the changes adopted in the 2006 IBC and, in regards to foundations, the on-grade mat foundation has become a more attractive design because, as an engineered system, it already accommodates the 2008 design recommendations, and required no major modifications to bring it into compliance.

  6. Reinforced concrete - Wikipedia

    en.wikipedia.org/wiki/Reinforced_concrete

    The minimum concrete cover is normally regulated by design or building codes. If the reinforcement is too close to the surface, early failure due to corrosion may occur. The concrete cover depth can be measured with a cover meter. However, carbonated concrete incurs a durability problem only when there is also sufficient moisture and oxygen to ...

  7. Reinforced concrete column - Wikipedia

    en.wikipedia.org/wiki/Reinforced_Concrete_Column

    The ACI codebook puts an upward limit on the spacing between ties. ACI Code 7.10.5: Vertical spacing of ties shall not exceed 16 longitudinal bar diameters, 48 tie bar or wire diameters, or least dimension of the compression member. If the ties are spaced too far apart, the column will experience shearfailure and barrel in between the ties. [4]

  8. Concrete cover - Wikipedia

    en.wikipedia.org/wiki/Concrete_cover

    Generally, larger diameter reinforcement bars require more concrete cover than smaller ones. In most cases, local building codes and engineering standards specify the minimum required concrete cover for various types of structures. It is important to adhere to these requirements to ensure the safety and longevity of the structure.

  9. Shallow foundation - Wikipedia

    en.wikipedia.org/wiki/Shallow_foundation

    Slab-on-grade or floating slab foundations are a structural engineering practice whereby the concrete slab that is to serve as the foundation for the structure is formed from a mold set into the ground. The concrete is then placed into the mold, leaving no space between the ground and the structure.