When.com Web Search

  1. Ad

    related to: scfm vs acfm chart for ac motors 1 4 hp

Search results

  1. Results From The WOW.Com Content Network
  2. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  3. NEMA size - Wikipedia

    en.wikipedia.org/wiki/NEMA_size

    NEMA (National Electrical Manufacturers Association) contactors and motor starters are rated by sizes. These sizes are grouped by rated current and power . [ 1 ] [ 2 ]

  4. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    Actual cubic foot per minute (ACFM) is the volume of gas flowing anywhere in a system, taking into account its temperature and pressure. If the system were moving a gas at exactly the "standard" condition, then ACFM would equal SCFM. This usually is not the case as the most important change between these two definitions is the pressure.

  5. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    With C v = 1.0 and 200 psia inlet pressure, the flow is 100 standard cubic feet per minute (scfm). The flow is proportional to the absolute inlet pressure, so the flow in scfm would equal the C v flow coefficient if the inlet pressure were reduced to 2 psia and the outlet were connected to a vacuum with less than 1 psi absolute pressure (1.0 ...

  6. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    For example, an unloaded motor of = 5,700 rpm/V supplied with 11.1 V will run at a nominal speed of 63,270 rpm (= 5,700 rpm/V × 11.1 V). The motor may not reach this theoretical speed because there are non-linear mechanical losses.

  7. Alternating current field measurement - Wikipedia

    en.wikipedia.org/wiki/Alternating_Current_Field...

    Alternating current field measurement (ACFM) is an electromagnetic technique for non-destructive testing detection and sizing of surface breaking discontinuities. It was derived from the methods used in eddy-current testing and works on all metals, ferrous or non-ferrous. Since it doesn't require direct electrical contact with the surface it ...

  8. Fractional-horsepower motor - Wikipedia

    en.wikipedia.org/wiki/Fractional-horsepower_motor

    There is no defined minimum output, however, it is generally accepted that a motor with a frame size of less than 35mm square can be referred to as a 'micro-motor'. Fractional-horsepower electric motors are exempt from the US Energy Policy Act of 2005 and the new EN 60034-30:2009 [ 1 ] ruling of European directive 2005/32/EC [ 2 ] concerning ...

  9. AC motor - Wikipedia

    en.wikipedia.org/wiki/AC_motor

    An AC motor is an electric motor driven by an alternating current (AC). The AC motor commonly consists of two basic parts, an outside stator having coils supplied with alternating current to produce a rotating magnetic field , and an inside rotor attached to the output shaft producing a second rotating magnetic field.