When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Electrical fault - Wikipedia

    en.wikipedia.org/wiki/Electrical_fault

    A "thumper" test set applies a high-energy, high-voltage pulse to the cable. Fault location is done by listening for the sound of the discharge at the fault. While this test contributes to damage at the cable site, it is practical because the faulted location would have to be re-insulated when found in any case. [7]

  3. Residual-current device - Wikipedia

    en.wikipedia.org/wiki/Residual-current_device

    A residual-current device (RCD), residual-current circuit breaker (RCCB) or ground fault circuit interrupter (GFCI) [a] is an electrical safety device, more specifically a form of Earth-leakage circuit breaker, that interrupts an electrical circuit when the current passing through line and neutral conductors of a circuit is not equal (the term residual relating to the imbalance), therefore ...

  4. Fault indicator - Wikipedia

    en.wikipedia.org/wiki/Fault_indicator

    In electric power distribution networks, a fault indicator is a device which provides visual or remote indication of a fault on the electric power system. Also called a faulted circuit indicator (FCI), [1] the device is used in electric power distribution networks as a means of automatically detecting and identifying faults to reduce outage time.

  5. Fuse cutout - Wikipedia

    en.wikipedia.org/wiki/Fuse_cutout

    In electrical distribution, a fuse cutout or cut-out fuse (often referred to as a cutout) is a combination of a fuse and a switch, used in primary overhead feeder lines and taps to protect distribution transformers from current surges and overloads. An overcurrent caused by a fault in the transformer or customer circuit will cause the fuse to ...

  6. Circuit breaker - Wikipedia

    en.wikipedia.org/wiki/Circuit_breaker

    A small circuit breaker typically has a manual control lever to switch the circuit off or reset a tripped breaker, while a larger unit may use a solenoid to trip the mechanism, and an electric motor to restore energy to springs (which rapidly separate contacts when the breaker is tripped). The circuit breaker contacts must carry the load ...

  7. Fuse (electrical) - Wikipedia

    en.wikipedia.org/wiki/Fuse_(electrical)

    Some fuses allow a special purpose micro switch or relay unit to be fixed to the fuse body. When the fuse element blows, the indicating pin extends to activate the micro switch or relay, which, in turn, triggers an event. Some fuses for medium-voltage applications use two or three separate barrels and two or three fuse elements in parallel.

  8. Resettable fuse - Wikipedia

    en.wikipedia.org/wiki/Resettable_fuse

    Resettable fuses - PolySwitch devices. A resettable fuse or polymeric positive temperature coefficient device (PPTC) is a passive electronic component used to protect against overcurrent faults in electronic circuits. The device is also known as a multifuse or polyfuse or polyswitch.

  9. Arc-fault circuit interrupter - Wikipedia

    en.wikipedia.org/wiki/Arc-fault_circuit_interrupter

    This AFCI (the circuit breaker with the yellow label) is an older generation AFCI circuit breaker. The current (as of 2013) devices are referred to as "combination type." An arc-fault circuit interrupter ( AFCI ) or arc-fault detection device ( AFDD ) [ 1 ] is a circuit breaker that breaks the circuit when it detects the electric arcs that are ...

  1. Related searches lights not working fuse tripped breaker switch location list

    lights not working fuse tripped breaker switch location list maptripped breaker won't reset