When.com Web Search

  1. Ads

    related to: air handler condensation draining problems in home

Search results

  1. Results From The WOW.Com Content Network
  2. Dehumidifier - Wikipedia

    en.wikipedia.org/wiki/Dehumidifier

    When the height of the air handler (containing the evaporator) is above the level of the surface drains used for rainwater, the condensate drain lines can often be routed into them. Air handlers located below grade level, e.g. the basement of a house, may need to use a condensate pump to lift the water to a surface drain.

  3. Condensate pump - Wikipedia

    en.wikipedia.org/wiki/Condensate_pump

    The output of small condensate pumps is usually routed to a sewer, plumbing drain, or the outside world via PVC plastic tubing (condensate drain line). In some locales, condensate water is not permitted to enter a sewer system and must be directed to the outside of the house, usually into the leader/gutter downspout system, or the stormwater ...

  4. Fan coil unit - Wikipedia

    en.wikipedia.org/wiki/Fan_coil_unit

    The fan coil unit will contain a purpose designed drip tray with drain connection for this purpose. The simplest means to drain the condensate from multiple fan coil units will be by a network of pipework laid to falls to a suitable point. Alternatively a condensate pump may be employed where space for such gravity pipework is limited.

  5. Air handler - Wikipedia

    en.wikipedia.org/wiki/Air_handler

    An air handler, or air handling unit (often abbreviated to AHU), is a device used to regulate and circulate air as part of a heating, ventilating, and air-conditioning system. [1] An air handler is usually a large metal box containing a blower , furnace or A/C elements, filter racks or chambers, sound attenuators , and dampers . [ 2 ]

  6. Heat recovery ventilation - Wikipedia

    en.wikipedia.org/wiki/Heat_recovery_ventilation

    Diagramatic operation of a thermal wheel Ljungström Air Preheater by Swedish engineer Fredrik Ljungström (1875–1964). A thermal wheel, also known as a rotary heat exchanger, or rotary air-to-air enthalpy wheel, energy recovery wheel, or heat recovery wheel, is a type of energy recovery heat exchanger positioned within the supply and exhaust air streams of air-handling units or rooftop ...

  7. Chilled beam - Wikipedia

    en.wikipedia.org/wiki/Chilled_beam

    A chilled beam is a type of radiation/convection HVAC system designed to heat and cool large buildings through the use of water. [1] This method removes most of the zone sensible local heat gains and allows the flow rate of pre-conditioned air from the air handling unit to be reduced, lowering by 60% to 80% the ducted design airflow rate and the equipment capacity requirements.

  1. Ad

    related to: air handler condensation draining problems in home