For example, medical device manufacturers design their sterilization processes for an extremely low SAL, such as 10 −6, which is a 1 in 1,000,000 chance of a non-sterile unit. SAL also describes the killing efficacy of a sterilization process. A very effective sterilization process has a very low SAL.
ISO 11737 Sterilization of medical devices – Microbiological methods ISO 11737-1:2006 Part 1: Determination of a population of microorganisms on products; ISO 11737-2:2009 Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process; ISO/IEC 11756:1999 Information technology - Programming ...
Microorganisms growing on an agar plate. Sterilization (British English: sterilisation) refers to any process that removes, kills, or deactivates all forms of life (particularly microorganisms such as fungi, bacteria, spores, and unicellular eukaryotic organisms) and other biological agents (such as prions or viruses) present in fluid or on a specific surface or object. [1]
Geobacillus stearothermophilus (previously Bacillus stearothermophilus) [1] [2] is a rod-shaped, Gram-positive bacterium and a member of the phylum Bacillota.The bacterium is a thermophile and is widely distributed in soil, hot springs, ocean sediment, and is a cause of spoilage in food products.
The aim of bioburden testing is to measure the total number of viable micro-organisms (total microbial count) on a medical device prior to its final sterilization before implantation or use. [ 2 ] 21 C.F.R. 211.110 (a)(6) states that bioburden in-process testing must be conducted pursuant to written procedures during the manufacturing process ...
In microbiology, in the context of a sterilization procedure, the D-value or decimal reduction time (or decimal reduction dose) is the time (or dose of an antimicrobial drug) required, at a given condition (e.g. temperature) or set of conditions, to achieve a one-log reduction, that is, to kill 90% of relevant microorganisms. [1]
"F 0" is defined as the number of equivalent minutes of steam sterilization at temperature 121.1 °C (250 °F) delivered to a container or unit of product calculated using a z-value of 10 °C. The term F-value or "F Tref/z " is defined as the equivalent number of minutes to a certain reference temperature (T ref ) for a certain control ...
Equipment used in aseptic processing of food and beverages must be sterilized before processing and remain sterile during processing. [1] When designing aseptic processing equipment there are six basic requirements to consider: the equipment must have the capability of being cleaned thoroughly, it must be able to be sterilized with steam, chemicals, or high-temperature water, sterilization ...