When.com Web Search

  1. Ads

    related to: cable size and overall diameter table for 50 mile distance calculator

Search results

  1. Results From The WOW.Com Content Network
  2. Circular mil - Wikipedia

    en.wikipedia.org/wiki/Circular_mil

    For example, one common wire size used in the NEC has a conductor diameter of 0.5 inches, or 500 mils, and thus a cross-section of = circular mils, written as 250 kcmil or 250 MCM, which is the first size larger than 0000 AWG used within the NEC.

  3. American wire gauge - Wikipedia

    en.wikipedia.org/wiki/American_wire_gauge

    Wire sized 1 AWG is referred to as "one gauge" or "No. 1" wire; similarly, thinner sizes are pronounced "x gauge" or "No. x" wire, where x is the positive-integer AWG number. Consecutive AWG wire sizes thicker than No. 1 wire are designated by the number of zeros: No. 0, often written 1/0 and referred to as "one aught" wire

  4. Wire gauge - Wikipedia

    en.wikipedia.org/wiki/Wire_gauge

    No. 7/0, the largest size, is 0.50 inches (500 mils or 12.7 mm) in diameter (250 000 circular mils in cross-sectional area), and the smallest, No. 50, is 0.001 inches (1 mil or 25.4 μm) in diameter (1 circular mil [cross-sectional area] or 0.7854 millionths of a square inch).

  5. Cable length - Wikipedia

    en.wikipedia.org/wiki/Cable_length

    A cable in this usage cable is a thick rope or by transference a chain cable. [1] The OED gives quotations from c. 1400 onwards. A cable's length (often "cable length" or just "cable") is simply the standard length in which cables came, which by 1555 had settled to around 100 fathoms (600 ft; 180 m) or 1 ⁄ 10 nautical mile (0.19 km; 0.12 mi). [1]

  6. Standard wire gauge - Wikipedia

    en.wikipedia.org/wiki/Standard_wire_gauge

    A table of the gauge numbers and wire diameters is shown below. [1] [2] The basis of the system is the thou (or mil in US English), or 0.001 in. Sizes are specified as wire diameters, stated in thou and tenths of a thou (mils and tenths). The wire diameter diminishes with increasing size number.

  7. Electrical length - Wikipedia

    en.wikipedia.org/wiki/Electrical_length

    The phase velocity at which electrical signals travel along a transmission line or other cable depends on the construction of the line. Therefore, the wavelength corresponding to a given frequency varies in different types of lines, thus at a given frequency different conductors of the same physical length can have different electrical lengths.

  8. IEC 60228 - Wikipedia

    en.wikipedia.org/wiki/IEC_60228

    Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...

  9. Mineral-insulated copper-clad cable - Wikipedia

    en.wikipedia.org/wiki/Mineral-insulated_copper...

    Overall diameter: 5 – >50 mm Minimum bend radius: 6 × diameter if less than 19 mm od, 12 × diameter if outside diameter is greater than 19 mm Weight: 73–3,300 kilograms per kilometre (260–11,710 lb/mi), 73–3,300 g/m, 259–11,708.4 lbs/mi Finish