The standard ASTM B258-02 (2008), Standard Specification for Standard Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Used as Electrical Conductors, defines the ratio between successive sizes to be the 39th root of 92, or approximately 1.1229322. [3]
Comparison of SWG (red), AWG (blue) and IEC 60228 (black) wire gauge sizes from 0.03 to 200 mm² to scale on a 1 mm grid – in the SVG file, hover over a size to highlight it. In engineering applications, it is often most convenient to describe a wire in terms of its cross-section area, rather than its diameter, because the cross section is directly proportional to its strength and weight ...
In commerce, the sizes of wire are estimated by devices, also called gauges, which consist of plates of circular or oblong form having notches of different widths around their edges to receive wire and sheet metals of different thicknesses. Each notch is stamped with a number, and the wire or sheet, which just fits a given notch, is stated to ...
In modern applications, wire size is more commonly measured in terms of cross-sectional area, expressed in square millimeters, particularly for electrical installation cables. The current British Standard for metallic materials, including wires and sheets, is BS 6722:1986, which exclusively uses metric measurements .
where is the length of the conductor, measured in metres [m], A is the cross-section area of the conductor measured in square metres [m 2], σ is the electrical conductivity measured in siemens per meter (S·m −1), and ρ is the electrical resistivity (also called specific electrical resistance) of the material, measured in ohm-metres (Ω·m ...
Electrical length is widely used with a graphical aid called the Smith chart to solve transmission line calculations. A Smith chart has a scale around the circumference of the circular chart graduated in wavelengths and degrees, which represents the electrical length of the transmission line from the point of measurement to the source or load.
where is the length of the conductor, measured in metres (m), A is the cross-sectional area of the conductor measured in square metres (m 2), σ is the electrical conductivity measured in siemens per meter (S·m −1), and ρ is the electrical resistivity (also called specific electrical resistance) of the material, measured in ohm-metres (Ω ...
IEC 62219 Overhead electrical conductors – Formed wire, concentric lay, stranded conductors; IEC 62220 Medical electrical equipment – Characteristics of digital X-ray imaging devices; IEC TR 62221 Optical fibres – Measurement methods – Microbending sensitivity; IEC TR 62222 Fire performance of communication cables installed in buildings