Data rate versus line length chart, from RS-422 Annex A.1. Several key advantages offered by this standard include the differential receiver, a differential driver and data rates as high as 10 megabits per second at 12 meters (40 ft). Since the signal quality degrades with cable length, the maximum data rate decreases as cable length increases.
English: Data Rate / Line Length chart from RS-422 Annex A. (This chart is not in RS-485). This chart is not an absolute limit, but a conservative guide based on empirical data of 24AWG telephone cable. Cable length may be extended from this chart.
The AC effects of the cable limit the quality of the signal and limit the cable length to short distances when high data rates are used. Examples of data rate and cable length combinations vary from 90 kbit/s at 1.2 km to 10 Mbit/s at 5m for RS-422.
MIL-STD-1553B does not specify the length of the cable. However, the maximum length of cable is directly related to the gauge of the cable conductor and time delay of the transmitted signal. A smaller conductor attenuates the signal more than a larger conductor. Typical propagation delay for a 1553B cable is 1.6 nanoseconds per foot.
The ARINC 429 unit of transmission is a fixed-length 32-bit frame, which the standard refers to as a 'word'. The bits within an ARINC 429 word are serially identified from Bit Number 1 to Bit Number 32 [4] or simply Bit 1 to Bit 32. The fields and data structures of the ARINC 429 word are defined in terms of this numbering.
RS-485, like RS-422, can be made full-duplex by using four wires. [8] Since RS-485 is a multi-point specification, however, this is not necessary or desirable in many cases. RS-485 and RS-422 can interoperate with certain restrictions.
The maximum working length of a cable varies depending on the characteristics of the transmitters and receivers, the baud rate on the cable, and the capacitance and electrical impedance of the cable. The RS-232 standard states that a compliant port must provide defined signal characteristics for a capacitive load of 2500 pF. This does not ...
RS-423 systems can transmit data on cables as long as 1,200 meters (3,900 ft). [ dubious – discuss ] It is closely related to RS-422 , which used the same signaling systems but on a different wiring arrangement: RS-423 differed primarily in that it had a single return pin instead of one for each data pin.