Search results
Results From The WOW.Com Content Network
A highly damped circuit will fail to resonate at all, when not driven. A circuit with a value of resistor that causes it to be just on the edge of ringing is called critically damped. Either side of critically damped are described as underdamped (ringing happens) and overdamped (ringing is suppressed).
Damped oscillation is a typical transient response, where the output value oscillates until finally reaching a steady-state value.. In electrical engineering and mechanical engineering, a transient response is the response of a system to a change from an equilibrium or a steady state.
The damping ratio is a system parameter, denoted by ζ ("zeta"), that can vary from undamped (ζ = 0), underdamped (ζ < 1) through critically damped (ζ = 1) to overdamped (ζ > 1). The behaviour of oscillating systems is often of interest in a diverse range of disciplines that include control engineering , chemical engineering , mechanical ...
A block diagram of a PID controller in a feedback loop. r ( t ) is the desired process variable (PV) or setpoint (SP), and y ( t ) is the measured PV. The distinguishing feature of the PID controller is the ability to use the three control terms of proportional, integral and derivative influence on the controller output to apply accurate and ...
Step response of a damped harmonic oscillator; curves are plotted for three values of μ = ω 1 = ω 0 √ 1 − ζ 2. Time is in units of the decay time τ = 1/(ζω 0). The value of the damping ratio ζ critically determines the behavior of the system. A damped harmonic oscillator can be:
For applications in control theory, according to Levine (1996, p. 158), rise time is defined as "the time required for the response to rise from x% to y% of its final value", with 0% to 100% rise time common for underdamped second order systems, 5% to 95% for critically damped and 10% to 90% for overdamped ones. [6]
Finally, if it is critically damped, it has an equal amount of deflection and controlling torque, thus allowing the pointer to quickly find the correct value, without the system oscillating past that value. [5] Critically damped means the machine has the right amount of damping torque and is ready to be used for experiments.
Campbell Diagram of a steam turbine. Analysis shows that there are well-damped critical speed at lower speed range. Another critical speed at mode 4 is observed at 7810 rpm (130 Hz) in dangerous vicinity of nominal shaft speed, but it has 30% damping - enough to safely ignore it.