When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Standard cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Standard_cubic_feet_per_minute

    For example, a mass flow rate of 1,000 kg/h of air at 1 atmosphere of absolute pressure is 455 SCFM when defined at 32 °F (0 °C) but 481 SCFM when defined at 60 °F (16 °C). Due to the variability of the definition and the consequences of ambiguity, it is best engineering practice to state what standard conditions are used when communicating ...

  3. Flow coefficient - Wikipedia

    en.wikipedia.org/wiki/Flow_coefficient

    SG is the specific gravity of the fluid (for water = 1), ΔP is the pressure drop across the valve (expressed in psi). In more practical terms, the flow coefficient C v is the volume (in US gallons) of water at 60 °F (16 °C) that will flow per minute through a valve with a pressure drop of 1 psi (6.9 kPa) across the valve.

  4. Actual cubic feet per minute - Wikipedia

    en.wikipedia.org/wiki/Actual_cubic_feet_per_minute

    Actual cubic feet per minute (ACFM) is a unit of volumetric flow. It is commonly used by manufacturers of blowers and compressors. [1] This is the actual gas delivery with reference to inlet conditions, whereas cubic foot per minute (CFM) is an unqualified term and should only be used in general and never accepted as a specific definition without explanation.

  5. Water flow test - Wikipedia

    en.wikipedia.org/wiki/Water_flow_test

    A process to perform a water flow test is explained in the model fire codes as published by NFPA (National Fire Protection Association). If a water supply source is considered weak compared to what is required by the sprinkler system design hydraulic calculation, the water pressure can be boosted by means of a fire pump.

  6. Useful conversions and formulas for air dispersion modeling

    en.wikipedia.org/wiki/Useful_conversions_and...

    If a gaseous emission sample is analyzed and found to contain water vapor and a pollutant concentration of say 40 ppmv, then 40 ppmv should be designated as the "wet basis" pollutant concentration. The following equation can be used to correct the measured "wet basis" concentration to a "dry basis" concentration: [3]

  7. Fixture unit - Wikipedia

    en.wikipedia.org/wiki/Fixture_unit

    A Fixture Unit is not a flow rate unit but a design factor. A fixture unit is equal to 1 cubic foot (0.028 m 3) of water drained in a 1 + 1 ⁄ 4 inches (32 mm) diameter pipe over one minute. [2] One cubic foot of water is roughly 7.48 US gallons (28.3 L; 6.23 imp gal). A Fixture Unit is used in plumbing design for both water supply and waste ...

  8. Air flow meter - Wikipedia

    en.wikipedia.org/wiki/Air_flow_meter

    An air flow meter is a device similar to an anemometer that measures air flow, i.e. how much air is flowing through a tube. It does not measure the volume of the air passing through the tube, it measures the mass of air flowing through the device per unit time, though Thus air flow meters are simply an application of mass flow meters for the ...

  9. Flow measurement - Wikipedia

    en.wikipedia.org/wiki/Flow_measurement

    This is the most commonly used measurement system for measuring water supply in houses. The fluid, most commonly water, enters in one side of the meter and strikes the nutating disk, which is eccentrically mounted. The disk must then "wobble" or nutate about the vertical axis, since the bottom and the top of the disk remain in contact with the ...