A normal chest X-ray after placement of an ICD, showing the ICD generator in the upper left chest and the ICD lead in the right ventricle of the heart. Note the 2 opaque coils along the ICD lead. The process of implantation of an ICD system is similar to implantation of an artificial pacemaker. In fact, ICDs are composed of an ICD generator and ...
Until the early 1950s, defibrillation of the heart was possible only when the chest cavity was open during surgery. The technique used an alternating voltage from a 300 or greater volt source derived from standard AC power, delivered to the sides of the exposed heart by "paddle" electrodes where each electrode was a flat or slightly concave ...
Impedance cardiography (ICG) is a non-invasive technology measuring total electrical conductivity of the thorax and its changes in time to process continuously a number of cardiodynamic parameters, such as stroke volume (SV), heart rate (HR), cardiac output (CO), ventricular ejection time (VET), pre-ejection period and used to detect the impedance changes caused by a high-frequency, low ...
Pad placement for electrical cardioversion a cardiac arrhythmia may be either anterior-posterior or anterior-lateral. In an anterior-posterior setup one pad is placed on the chest and the other pad is placed on the back. In an anterior-lateral setup, one pad is placed on the chest and the other pad is placed along the left midaxillary line.
S-ICD lead and generator position. Subcutaneous implantable cardioverter defibrillator, or S-ICD, is an implantable medical device for detecting and terminating ventricular tachycardia and ventricular fibrillation in patients at risk of sudden cardiac arrest. [1]
The use of cardiac defibrillation started in 1947 - first in an open chest and ten years later through a closed chest with high energy levels. In 1972, cardiac defibrillation with intracardiac electrodes delivering much less energy of as low as 30 joules was established, following the development of portable units delivering high energy levels ...
After defibrillation, chest compressions should be continued for two minutes before another rhythm check. [30] This is based on a compression rate of 100-120 compressions per minute, a compression depth of 5–6 centimeters into the chest, full chest recoil, and a ventilation rate of 10 breath ventilations per minute. [30]
The Seldinger technique is used for angiography, insertion of chest drains and central venous catheters, insertion of PEG tubes using the push technique, insertion of the leads for an artificial pacemaker or implantable cardioverter-defibrillator, and numerous other interventional medical procedures.