When.com Web Search

  1. Ad

    related to: how to minimize resistance change in electricity line and run time and work

Search results

  1. Results From The WOW.Com Content Network
  2. Voltage reduction - Wikipedia

    en.wikipedia.org/wiki/Voltage_reduction

    Either purchase power from another utility, usually at substantial prices, or reduce demand. Often utilities use load management systems to turn off customers' air conditioners, water heaters, and pool pumps to reduce demand. Voltage reduction has become another option for utilities to reduce demand—typically unbeknownst to the customer.

  3. Impedance matching - Wikipedia

    en.wikipedia.org/wiki/Impedance_matching

    This causes the load seen by the power line to be purely resistive. For a given true power required by a load this minimizes the true current supplied through the power lines, and minimizes power wasted in the resistance of those power lines. For example, a maximum power point tracker is used to extract the maximum power from a solar panel and ...

  4. Copper loss - Wikipedia

    en.wikipedia.org/wiki/Copper_loss

    For low-frequency applications, the power loss can be minimized by employing conductors with a large cross-sectional area, made from low-resistivity metals.With high-frequency currents, the proximity effect and skin effect cause the current to be unevenly distributed across the conductor, increasing its effective resistance, and making loss calculations more difficult.

  5. Electric power transmission - Wikipedia

    en.wikipedia.org/wiki/Electric_power_transmission

    As of 2022, more than 10,000 power plant and energy storage projects were awaiting permission to connect to the US grid — 95% were zero-carbon resources. New power lines can take 10 years to plan, permit, and build. [33] Traditional power lines use a steel core surrounded by aluminum strands (Aluminium-conductor steel-reinforced cable).

  6. Contact resistance - Wikipedia

    en.wikipedia.org/wiki/Contact_resistance

    It may also vary with time (most often decreasing) in a process known as resistance creep. Electrical contact resistance is also called interface resistance, transitional resistance, or the correction term. Parasitic resistance is a more general term, of which it is usually assumed that contact resistance is a major component.

  7. Voltage drop - Wikipedia

    en.wikipedia.org/wiki/Voltage_drop

    The simplest way to reduce voltage drop is to increase the diameter of the conductor between the source and the load, which lowers the overall resistance. In power distribution systems, a given amount of power can be transmitted with less voltage drop if a higher voltage is used. More sophisticated techniques use active elements to compensate ...

  8. Negative resistance - Wikipedia

    en.wikipedia.org/wiki/Negative_resistance

    An I–V curve, showing the difference between static resistance (inverse slope of line B) and differential resistance (inverse slope of line C) at a point (A).. The resistance between two terminals of an electrical device or circuit is determined by its current–voltage (I–V) curve (characteristic curve), giving the current through it for any given voltage across it. [18]

  9. Inrush current limiter - Wikipedia

    en.wikipedia.org/wiki/Inrush_current_limiter

    An NTC thermistor's resistance is low at high temperatures. When the circuit is closed, the thermistor's resistance limits the initial current. After some time, current flow heats the thermistor, and its resistance changes to a lower value, allowing current to flow uninterrupted. It is inherently impossible for 100% of supply voltage to appear ...