Oxygen enriched treatment gases and Oxygen may be used. Air may be used if nothing better is available. If oxygen breathing is interrupted no compensation to the times is required. Oxygen partial pressure may not exceed 3 ata (3 bar). Maximum depth 165 fsw (50 msw) Time at 165 fsw optional from 30 minutes to 2 hours including compression
Z88.2 notes that these SCBAs normally use compressed air, but can also use cryogenic air or compressed oxygen. However, the standard warns that "the actual service time is usually less than the NIOSH rated service time". If compressed air is used, Z88.2 requires the use of "CGA G7.1–2011 Grade D breathing air". [14]
An oxygen tank is especially dangerous because the gas is stored at a pressure of 21 MPa (3,000 psi; 210 atm)) when full. If the tank falls over and damages the valve, the tank can be jettisoned by the compressed oxygen escaping the cylinder at high speed. Tanks in this state are capable of breaking through a brick wall. [19]
This is a big advantage in mobile emergencies. The option to fill standard oxygen cylinders (e.g., 50 L at 200 bar = 10,000 L each) with high-pressure boosters, to ensure automatic failover to previously filled reserve cylinders and to ensure the oxygen supply chain, e.g., in case of power failure, is given with those systems.
A set of MAPP and oxygen cylinders is used for oxy-fuel welding and cutting.. MAPP gas was a trademarked name, belonging to The Linde Group, a division of the former global chemical giant Union Carbide, for a fuel gas based on a stabilized mixture of methylacetylene (propyne), propadiene and propane.
The pin index safety system uses a face seal between the cylinder valve and the associated yoke clamp. There are two holes in specific positions on the cylinder valve body below the outlet port , in positions associated with the gas mixture, which prevent connection of the cylinder to a yoke or pressure regulator with a mis-matched set of pins.
Medical use liquid oxygen airgas tanks are typically 2.4 MPa (350 psi). [citation needed] All equipment coming into contact with high pressure oxygen must be "oxygen clean" and "oxygen compatible", to reduce the risk of fire. [3] [4] "Oxygen clean" means the removal of any substance that could act as a source of ignition. "Oxygen compatible ...
The pressure vessel is a seamless cylinder normally made of cold-extruded aluminum or forged steel. [5] Filament wound composite cylinders are used in fire fighting breathing apparatus and oxygen first aid equipment because of their low weight, but are rarely used for diving, due to their high positive buoyancy.