When.com Web Search

  1. Ad

    related to: tempering valve location on furnace heater diagram problems

Search results

  1. Results From The WOW.Com Content Network
  2. HVAC control system - Wikipedia

    en.wikipedia.org/wiki/HVAC_control_system

    Doing these three steps are super essential and is the key to keeping an HVAC system running for a long time. A customer should do these three steps every couple of months or when it is suspected problem with the HVAC system. [citation needed] Some signs that could lead to a potential problem is if the HVAC system does not provide air cool enough.

  3. Furnace (central heating) - Wikipedia

    en.wikipedia.org/wiki/Furnace_(central_heating)

    Diagram of natural draft gas furnace, early 20th century. The first category of furnaces is natural draft, atmospheric burner furnaces. These furnaces consisted of cast-iron or riveted-steel heat exchangers built within an outer shell of brick, masonry, or steel. The heat exchangers were vented through brick or masonry chimneys.

  4. Thermostatic mixing valve - Wikipedia

    en.wikipedia.org/wiki/Thermostatic_mixing_valve

    Tempering valves for use on hot water heat distribution systems; High flow rates suitable for use in under floor (radiant) heating applications; Allows water to be stored at a higher temperature; Group Control. These provide a uniform distribution temperature for all hot water outlets in a household. Designed for multi-point applications

  5. Thermostat - Wikipedia

    en.wikipedia.org/wiki/Thermostat

    A thermostatic mixing valve uses a wax pellet to control the mixing of hot and cold water. A common application is to permit operation of an electric water heater at a temperature hot enough to kill Legionella bacteria (above 60 °C, 140 °F), while the output of the valve produces water that is cool enough to not immediately scald (49 °C, 120 ...

  6. Central heating - Wikipedia

    en.wikipedia.org/wiki/Central_heating

    A safety valve allows water to escape from the system when pressure becomes too high, and a valve can open to replenish water from the normal water supply if the pressure drops too low. Sealed systems offer an alternative to open-vent systems, in which steam can escape from the system, and gets replaced from the building's water supply via a ...

  7. Hydronics - Wikipedia

    en.wikipedia.org/wiki/Hydronics

    In general, valves nearest to the boiler should vent the slowest, and valves furthest from the boiler should vent the fastest. [citation needed] Ideally, steam should reach each valve and close each and every valve at the same time, so that the system can work at maximal efficiency; this condition is known as a "balanced" system. [citation needed]

  8. Heat trap - Wikipedia

    en.wikipedia.org/wiki/Heat_trap

    Heat traps are valves or loops of pipe on the cold water inlet and hot water outlet of water heaters. The heat traps allow cold water to flow into the water heater tank, but prevent unwanted natural convection and heated water to flow out of the tank. [1] [2] Newer water heaters have built-in heat traps.

  9. Muffle furnace - Wikipedia

    en.wikipedia.org/wiki/Muffle_furnace

    The doorway is closed by two fireclay blocks at E. High temperature muffle-furnace, maximum temperature is 1,473 K (1,200 °C; 2,192 °F). A muffle furnace or muffle oven (sometimes retort furnace in historical usage) is a furnace in which the subject material is isolated from the fuel and all of the products of combustion, including gases and ...