It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test), [1] locked rotor test or stalled torque test. [2] From this test, short-circuit current at normal voltage , power factor on short circuit, total leakage reactance , and starting torque of the motor can be found.
is the motor torque constant (SI unit, newton–metre per ampere, N·m/A), see below If two motors with the same K v {\displaystyle K_{\text{v}}} and torque work in tandem, with rigidly connected shafts, the K v {\displaystyle K_{\text{v}}} of the system is still the same assuming a parallel electrical connection.
Reduced starting current is desirable where the electrical grid is not of sufficient capacity, or where the driven load cannot withstand high starting torque. One basic method to reduce the starting current is with a reduced voltage autotransformer with taps at 50%, 65% and 80% of the applied line voltage; once the motor is started the ...
A motor soft starter is a device used with AC electrical motors to temporarily reduce the load and torque in the powertrain and electric current surge of the motor during start-up. This reduces the mechanical stress on the motor and shaft, as well as the electrodynamic stresses on the attached power cables and electrical distribution network ...
If the brushes are shifted counter-clockwise from the main magnetic axis, the motor will rotate in a counter-clockwise direction. Torque and speed control. The starting torque of a repulsion motor is determined by the angle of brush shift from the main magnetic axis. The maximum torque is obtained from a brush shift of 45 degrees.
Get AOL Mail for FREE! Manage your email like never before with travel, photo & document views. Personalize your inbox with themes & tabs. You've Got Mail!
This creates torque that pulls the rotor into alignment with the nearest pole of the stator field. At synchronous speed the rotor is thus "locked" to the rotating stator field. This cannot start the motor, so the rotor poles usually have squirrel-cage windings embedded in them, to provide torque below synchronous speed. The machine thus starts ...
By adjusting the shape of the bars in the rotor, the speed-torque characteristics of the motor can be changed, to minimize starting current or to maximize low-speed torque, for example. Squirrel-cage induction motors are very prevalent in industry, in sizes from below 1 kilowatt (1.3 hp) up to tens of megawatts (tens-of-thousand horsepower).