The goal of close coupled cooling is to bring heat transfer closest to its source: the equipment rack. By moving the air conditioner closer to the equipment rack a more precise delivery of inlet air and a more immediate capture of exhaust air is ensured. The proximity of the cooling system with the server cabinet allows a high-performance solution
The demands of server rooms are constantly changing as organizations evolve and grow and as technology changes. An essential part of computer room design is future proofing so that new requirements can be accommodated with minimal effort. As computing requirements grow, so will a server room's power and cooling requirements.
Rack cabinet is a typical enclosure for horizontally mounted servers. Air typically drawn in at the front of the rack and exhausted at the rear. Each cabinet can have additional cooling options; for example, they can have a Close Coupled Cooling attachable module or integrated with cabinet elements (like cooling doors in iDataPlex server rack).
A standard 19-inch server rack cabinet is typically 42u in height, 600 millimetres (24 in) wide, and 36 inches (914.40 mm) deep. [18] This comprises a volume of 974 L, or just under a cubic meter. Newer server rack cabinets come with adjustable mounting rails allowing the user to place the rails at a shorter depth if needed.
Power cooling density is a measure of how much square footage the center can cool at maximum capacity. [100] The cooling of data centers is the second largest power consumer after servers. The cooling energy varies from 10% of the total energy consumption in the most efficient data centers and goes up to 45% in standard air-cooled data centers.