When.com Web Search

  1. Ads

    related to: generator size calculator by amps

Search results

  1. Results From The WOW.Com Content Network
  2. Per-unit system - Wikipedia

    en.wikipedia.org/wiki/Per-unit_system

    Generally base values of power and voltage are chosen. The base power may be the rating of a single piece of apparatus such as a motor or generator. If a system is being studied, the base power is usually chosen as a convenient round number such as 10 MVA or 100 MVA. The base voltage is chosen as the nominal rated voltage of the system.

  3. Diesel generator - Wikipedia

    en.wikipedia.org/wiki/Diesel_generator

    A 200 kW Caterpillar diesel generator set in a sound attenuated enclosure used as an emergency backup at a sewage treatment substation in Atlanta, United States. A diesel generator (DG) (also known as a diesel GenSet) is the combination of a diesel engine with an electric generator (often an alternator) to generate electrical energy. [1]

  4. Motor constants - Wikipedia

    en.wikipedia.org/wiki/Motor_constants

    On the other hand, if the motor is driven as a generator, the no-load voltage between terminals is perfectly proportional to the RPM and true to the of the motor/generator. The terms K e {\displaystyle K_{\text{e}}} , [ 2 ] K b {\displaystyle K_{\text{b}}} are also used, [ 4 ] as are the terms back EMF constant , [ 5 ] [ 6 ] or the generic ...

  5. Induction generator - Wikipedia

    en.wikipedia.org/wiki/Induction_generator

    As an example, consider the use of a 10 hp, 1760 r/min, 440 V, three-phase induction motor (a.k.a. induction electrical machine in an asynchronous generator regime) as asynchronous generator. The full-load current of the motor is 10 A and the full-load power factor is 0.8.

  6. Engine–generator - Wikipedia

    en.wikipedia.org/wiki/Engine–generator

    The mid-size stationary engine–generator pictured here is a 100 kVA set which produces 415 V at around 110 A. It is powered by a 6.7-liter turbocharged Perkins Phaser 1000 Series engine, and consumes approximately 27 liters of fuel an hour, on a 400-liter tank.

  7. Prospective short-circuit current - Wikipedia

    en.wikipedia.org/wiki/Prospective_short-circuit...

    An isolated generator may be specially designed to ensure that it can source enough current on a short circuit to allow subordinate overcurrent protection devices to operate properly. Where an industrial system is fed from an electrical utility, the short circuit level at the point of connection may be specified, often with minimum and maximum ...

  1. Ads

    related to: generator size calculator by amps