  2. Air changes per hour - Wikipedia

    en.wikipedia.org/wiki/Air_changes_per_hour

    Air changes per hour, abbreviated ACPH or ACH, or air change rate is the number of times that the total air volume in a room or space is completely removed and replaced in an hour. If the air in the space is either uniform or perfectly mixed, air changes per hour is a measure of how many times the air within a defined space is replaced each hour.

  3. Ventilation (architecture) - Wikipedia

    en.wikipedia.org/wiki/Ventilation_(architecture)

    For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed ...

  4. Air filtration in operating rooms - Wikipedia

    en.wikipedia.org/wiki/Air_filtration_in...

    High-efficiency particulate air (HEPA) filter is at least 99.97% effective in removing particles ≥0.3 μm in diameter (as a reference, Aspergillus spores are 2.5–3.0 μm in diameter). [3] High-level HEPA filtration and increasing air changes per hour (ACH) can reduce particulate matter (PM) and bacterial concentrations in the operating room ...

  5. Infiltration (HVAC) - Wikipedia

    en.wikipedia.org/wiki/Infiltration_(HVAC)

    The infiltration rate is the volumetric flow rate of outside air into a building, typically in cubic feet per minute (CFM) or liters per second (LPS). The air exchange rate, (I), is the number of interior volume air changes that occur per hour, and has units of 1/h. The air exchange rate is also known as air changes per hour (ACH).

  6. Heating, ventilation, and air conditioning - Wikipedia

    en.wikipedia.org/wiki/Heating,_ventilation,_and...

    Air-side economizers also use outside air to condition spaces, but do so using fans, ducts, dampers, and control systems to introduce and distribute cool outdoor air when appropriate. An important component of natural ventilation is air change rate or air changes per hour: the hourly rate of ventilation divided by the volume of the space. For ...

  7. Glossary of HVAC terms - Wikipedia

    en.wikipedia.org/wiki/Glossary_of_HVAC_terms

    The hourly ventilation rate divided by the volume of a space. For perfectly mixed air or laminar flow spaces, this is equal to the number of times per hour that the volume the space is exchanged by mechanical and natural ventilation. Also called air change rate or air exchange rate. Abbreviated ACH or ac/hr. air conditioner

  8. Engineering controls - Wikipedia

    en.wikipedia.org/wiki/Engineering_controls

    [9]: 11–12 For general exhaust ventilation in laboratories, a nonrecirculating system is used with 4–12 air changes per hour when used in tandem with local exhaust ventilation, and sources of contamination are placed close to the air exhaust and downwind of workers, and away from windows or doors that may cause air drafts. [11]: 13

  9. Clean air delivery rate - Wikipedia

    en.wikipedia.org/wiki/Clean_Air_Delivery_Rate

    The clean air delivery rate (CADR) is a figure of merit that is the cubic feet per minute (CFM) of air that has had all the particles of a given size distribution removed. For air filters that have air flowing through them, it is the fraction of particles (of a particular size distribution) that have been removed from the air, multiplied by the ...