Search results
Results From The WOW.Com Content Network
The thermodynamic method is used for performance testing of pumps, flow meter calibration, system curve tests, and other applications. It is capable of achieving results with uncertainties of less than 1% in pump efficiency and less than 1.5% in flow [ 3 ] while being able to test piping configurations where other conventional pump testing ...
A metering pump moves a precise volume of liquid in a specified time period providing an accurate volumetric flow rate. [1] Delivery of fluids in precise adjustable flow rates is sometimes called metering. The term "metering pump" is based on the application or use rather than the exact kind of pump used, although a couple types of pumps are ...
Sonar flowmeters have the capacity of measuring the velocity of liquids or gases non-intrusively within the pipe and then leverage this velocity measurement into a flow rate by using the cross-sectional area of the pipe and the line pressure and temperature. The principle behind this flow measurement is the use of underwater acoustics.
If an NPSH A is say 10 bar then the pump you are using will deliver exactly 10 bar more over the entire operational curve of a pump than its listed operational curve. Example: A pump with a max. pressure head of 8 bar (80 metres) will actually run at 18 bar if the NPSH A is 10 bar. i.e.: 8 bar (pump curve) plus 10 bar NPSH A = 18 bar.
A backwater buildup effect occurs in a submerged flume. For a flow calculation, a depth measurement both upstream and downstream is needed. Although commonly thought of as occurring at higher flow rates, submerged flow can exist at any flow level as it is a function of downstream conditions.
This comprises measurement of flow (FE) at the pump discharge, this measurement is an input to a flow controller (FIC) whose set point is the minimum flow required through the pump(see diagram). As the flow reduces to the minimum flow value the controller acts to open a flow control valve (FCV) to recycle fluid from the discharge back to the ...
In fluid dynamics, total dynamic head (TDH) is the work to be done by a pump, per unit weight, per unit volume of fluid.TDH is the total amount of system pressure, measured in feet, where water can flow through a system before gravity takes over, and is essential for pump specification.
Measurement and interpretation of 2 and 3 phase multiphase flow can also be achieved by using alternative flow measurement technologies such as SONAR.SONAR meters apply the principles of underwater acoustics to measure flow regimes and; can be clamped on to wellheads and flow lines to measure the bulk (mean) fluid velocity of the total mixture which is then post-processed and analyzed along ...