When.com Web Search

Search results

  1. Results From The WOW.Com Content Network
  2. Left atrial volume - Wikipedia

    en.wikipedia.org/wiki/Left_atrial_volume

    The left atrial volume is commonly measured by echocardiography or magnetic resonance tomography.It is calculated from biplane recordings with the equation: = where A4c and A2c denote LA areas in 4- and 2-chamber views respectively, and L corresponds to the shortest long-axis length measured in either views.

  3. Left ventricular mass - Wikipedia

    en.wikipedia.org/wiki/Left_ventricular_mass

    Published normal ranges for LVMi are 49–115 g/m 2 for men and 43–95 g/m 2 for women. [1] [4] left ventricular hypertrophy (LVH) is defined as an abnormal increase in LVM, an important independent risk factor for cardiovascular morbidity and mortality.

  4. Mitral regurgitation - Wikipedia

    en.wikipedia.org/wiki/Mitral_regurgitation

    Mitral regurgitation, also known as mitral insufficiency or mitral incompetence, is the backward flow of blood from the left ventricle, through the mitral valve, and into the left atrium, when the left ventricle contracts, resulting in a systolic murmur radiating to the left armpit.

  5. Left ventricular hypertrophy - Wikipedia

    en.wikipedia.org/wiki/Left_ventricular_hypertrophy

    S in V 1 or V 2 ≥30 mm; R in V 5 or V 6 ≥30 mm; 3 ST-T Abnormalities: ST-T vector opposite to QRS without digitalis; ST-T vector opposite to QRS with digitalis; 3 1 Negative terminal P mode in V 1 1 mm in depth and 0.04 sec in duration (indicates left atrial enlargement) 3 Left axis deviation (QRS of −30° or more) 2 QRS duration ≥0.09 ...

  6. Monitor unit - Wikipedia

    en.wikipedia.org/wiki/Monitor_unit

    A monitor unit (MU) is a measure of machine output from a clinical accelerator for radiation therapy such as a linear accelerator or an orthovoltage unit. Monitor units are measured by monitor chambers, which are ionization chambers that measure the dose delivered by a beam and are built into the treatment head of radiotherapy linear accelerators.

  7. Aortic valve replacement - Wikipedia

    en.wikipedia.org/wiki/Aortic_valve_replacement

    The aortic valve is opened during systole, the driving force for it to open is the difference in pressure between the contracting left ventricle of the heart and the aorta. During cardiac diastole (when the heart chamber gets bigger) the aortic valve closes. [5] Aortic stenosis most commonly is the result of calcification of the cusps.

  8. Bruce protocol - Wikipedia

    en.wikipedia.org/wiki/Bruce_protocol

    Every 3 min the speed & incline of the treadmill are increased. [2] There are 7 such stages and only very fit athletes can complete all 7 stages. The modified Bruce Protocol is an alteration in the protocol so that the treadmill is initially horizontal rather than uphill, with the 1st few intervals increasing the treadmill slope only.

  9. Small arms ammunition pressure testing - Wikipedia

    en.wikipedia.org/wiki/Small_arms_ammunition...

    The test cartridge must be inserted into the chamber in such a way that the hole in the test cartridge case lines up with a gas port hole that channels the gas pressure from the cartridge case to the face of the sensor. The measurement accuracy of the pressure measurements with 21st century high-pressure sensors is expected to be ≤ 2%. [7]